Solar Lattice

Product

Huawei SmartLogger

ID
prod:huawei-smartlogger
IRI
https://solarlattice.org/kb/prod/huawei-smartlogger
Status
active
Also known as
SmartLogger, Smart Logger, SmartLogger1000, SmartLogger 1000, SmartLogger2000
Category
Monitoring and communications
Make
huawei
Product level
family

The Huawei SmartLogger is a Huawei monitoring data logger. It collects data from SUN2000 string inverters and can pass that data on to a PC or to network management software. Inverters connect to it over RS485. When there are several inverters, they are wired in a daisy chain, and the chain should stay within 1000 m from the last inverter to the logger. Every inverter on an RS485 route needs its own unique Modbus RTU address inside the range set on the SmartLogger. It also needs the same baud rate as the logger, or communication fails. You can view inverter energy yield, alarms and running status through the SmartLogger or its embedded WebUI. It can also be used to disable AFCI on the inverter. The SmartLogger can push CSV reports over FTP to third-party platforms such as PowerTrack. Use file Format 2 or higher, because Format 1 leaves out the logger's own data and the cumulative energy values. Huawei names fiber plus RS485 or PLC networking as SmartLogger networking scenarios. When you contact Huawei support, have the SmartLogger model and firmware version ready.

Claims

manufactured_by

c1 verified · fact Huawei

Listed as a component purchased from Huawei.

verified by: review-workflowverified on: 2026-10-24

uses_protocol

c2 drafted · lead RS-485

SUN2000 inverters connect to the SmartLogger over RS485, in daisy chains for multiple inverters.

c3 verified · fact Modbus RTU

Inverter RS485 protocol set to MODBUS RTU. Addresses must sit inside the SmartLogger's configured range with no duplicates, and the baud rate must match the SmartLogger.

verified by: review-workflowverified on: 2026-10-24

c4 drafted · lead FTP push

The SmartLogger can push CSV data reports by FTP to a third-party monitoring platform.

c5 drafted · lead Fiber optic link

Optical fiber plus RS485/PLC is named as an example SmartLogger networking scenario.

review note: support check: partial - The passage names Optical Fiber + RS485/PLC Networking as an example scenario, but it does not clearly say the SmartLogger uses a fiber optic link protocol.

c6 drafted · lead Power line communication

RS485/PLC networking is named as an example SmartLogger networking scenario.

review note: support check: partial - RS485/PLC networking is named as an example scenario, but the passage does not explicitly say the SmartLogger uses power line communication.

implements

c7 verified · fact Monitor key DER data

Shows inverter energy yield, alarms and running status.

verified by: review-workflowverified on: 2026-10-24

max_count

c8 drafted · lead ≤ 80 NUM

Scope: products Huawei SUN2000-25KTL-US / SUN2000-30KTL-US

Conditions: Total SUN2000 devices on up to three RS485 daisy chains connected to the SmartLogger

review note: support check: partial - Up to 80 devices on a maximum of three daisy chains is stated, but the passage does not tie it to the SUN2000-25/30KTL-US product scope.

c9 drafted · lead ≤ 6 NUM

Scope: products Huawei SUN2000-45KTL-US-HV-D0

Conditions: RS485 daisy chains when multiple SUN2000s connect to a PC through the SmartLogger2000

review note: support check: partial - The maximum of six daisy chains is stated for SmartLogger2000 with a PC, but the passage does not tie it to the 45KTL-US-HV-D0 product scope.

Referenced by