Huawei SUN2000-25KTL-US / SUN2000-30KTL-US

ID
prod:huawei-sun2000-25-30ktl-us
IRI
https://solarlattice.org/kb/prod/huawei-sun2000-25-30ktl-us
Status
active
Also known as
SUN2000-25KTL-US, SUN2000-30KTL-US, SUN2000-25-30KTL-US, SUN2000-(25KTL, 30KTL)-US
Category
Inverters
Make
huawei
Product level
family

The Huawei SUN2000-25KTL-US and SUN2000-30KTL-US are transformerless three-phase string inverters. They are rated at 25 kW and 30 kW of output power. Both models accept up to 1,000 V DC at the input, and their full-power MPPT window runs from 560 to 850 V DC. Each MPPT takes at most 25 A. The maximum continuous AC output current is 33 A on the 25 kW model and 40 A on the 30 kW model. The 25 kW model lists a maximum efficiency of 98.6% and a CEC efficiency of 98.0%. Built-in protection includes a DC input switch, reverse polarity protection, insulation resistance detection, PV string fault detection and Type II surge protection on both the DC and AC sides. The inverter has an arc fault circuit interrupter (AFCI) to UL 1699B Type I. Its alarms include DC Arc Fault and AFCI Self-Check Failure. All units support RS485 communication, and PLC is an option on some variants. Only one of these modes can be used at a time, so do not connect the RS485 cable when PLC is used. The DC connectors are Amphenol Helios H4, and the enclosure is rated Type 4X.

<!-- review notes

Claims

manufactured_by

c1 drafted · lead Huawei

rated_power

c2 verified · fact nominal 25 KiloW

Conditions: SUN2000-25KTL-US model, rated output power

verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c3 (same source; check the conditions)

c3 drafted · lead nominal 30 KiloW

Conditions: SUN2000-30KTL-US model, rated output power

review note: possible conflict with c2 (same source; check the conditions)

efficiency

c4 drafted · lead nominal 98.6 PERCENT

Conditions: Maximum efficiency, SUN2000-25KTL-US

review note: possible conflict with c5 (same source; check the conditions)

c5 drafted · lead nominal 98 PERCENT

Conditions: CEC efficiency, SUN2000-25KTL-US

review note: possible conflict with c4 (same source; check the conditions)

max_input_voltage

c6 drafted · lead ≤ 1000 V

Conditions: Both SUN2000-25KTL-US and SUN2000-30KTL-US

mppt_voltage_range

c7 drafted · lead 560–850 V

Conditions: Full power MPPT voltage range, DC, both models

max_input_current

c8 verified · fact ≤ 45 A

Conditions: Total DC input, SUN2000-25KTL-US

verified by: review-workflowverified on: 2026-10-24

c9 verified · fact ≤ 54 A

Conditions: Total DC input, SUN2000-30KTL-US

verified by: review-workflowverified on: 2026-10-24

c10 drafted · lead ≤ 25 A

Conditions: Per MPPT, both models

rated_output_current

c11 drafted · lead ≤ 33 A

Conditions: Maximum continuous AC output current, SUN2000-25KTL-US

c12 drafted · lead ≤ 40 A

Conditions: Maximum continuous AC output current, SUN2000-30KTL-US

uses_protocol

c13 drafted · lead RS-485

c14 drafted · lead Power line communication

Conditions: Optional; only on variants with PLC. Only one communication mode (PLC or RS485) can be used at a time.

lacks

c15 drafted · lead Power line communication

Conditions: Variant without PLC only

implements

c16 drafted · lead DC arc-fault protection

AFCI per UL 1699B, Type I

c18 drafted · lead Insulation monitoring

c19 drafted · lead Reverse polarity protection

c20 drafted · lead String monitoring

PV string fault detection

c21 verified · fact Surge protection

Type II on both DC and AC sides

verified by: review-workflowverified on: 2026-10-24

certified_to

c17 drafted · lead UL 1699B proposed

AFCI Type I

review note: support check: partial - The passages say AFCI is to UL 1699B Type I. They do not say the inverter is certified.; review: partial - The spec row lists AFCI to UL 1699B Type I for both models, but it never says the inverters are certified to that standard.

compatible_with

c22 drafted · lead Amphenol Helios H4 PV connector

DC connector fitted on the inverter