Product
Enphase IQ9N Microinverters (IQ9N-A, IQ9N-HPB)
- ID
prod:enphase-iq9n
- IRI
https://solarlattice.org/kb/prod/enphase-iq9n
- Status
- active
- Also known as
- IQ9N, IQ9N-A, IQ9N-HPB, IQ9N-A-US, IQ9N-A-DOM-US, IQ9N-A-DOM-US-HPB, IQ9N Microinverter
- Category
- Inverters
- Make
- enphase
- Product level
- family
The Enphase IQ9N is a family of GaN-based residential microinverters that includes the IQ9N-A-US, IQ9N-A-DOM-US and IQ9N-HPB variants. The IQ9N-A-DOM-US-HPB delivers up to 440 VA continuous at 240 V and 415 VA at 208 V, with maximum continuous output currents of 1.83 A and 2.0 A. Its peak efficiency is 97.8 percent at 240 V and 97.7 percent at 208 V. CEC weighted efficiency is 97.5 and 97.0 percent. The microinverter must stay connected to an IQ Gateway or IQ Combiner, or it may stop operating. The HPB variant uses the IQ Cable on its AC side and needs Staubli MC4 connectors on its DC port. IQ9N units can be added to existing IQ7 or IQ8 systems on the same gateway and IQ System Controller, both grid-tied and with backup. Adding IQ7 or IQ8 units to an existing IQ9N-HPB site is not allowed. Sunlight Jump Start grid-forming PV works only when the system contains IQ8 and IQ9N units and no IQ7 Series microinverters. The unit is Class II double-insulated and includes ground fault protection. A solid red LED indicates a DC Resistance Low, Power Off condition, which triggers when PV-to-earth resistance drops below roughly 7 kilohms.
<!-- review notes
- sentence 1: support check: partial - Passages show IQ9N-A-US, IQ9N-A-DOM-US and an IQ9N-HPB manual with GaN architecture and residential use, but they don't explicitly say the HPB is a variant in the same family.
- sentence 2: support check: partial - The currents are labeled by voltage, but the power values 440 and 415 are not explicitly labeled 240 V and 208 V, and 'up to' is only implied by 'maximum'.
- sentence 1: review: partial - The release notes support GaN-based residential IQ9N-A-US and IQ9N-A-DOM-US, but the HPB variant is evidenced only by a manual title, with no passage stating it is GaN-based or part of the same family.
-->
Claims
manufactured_by
c1 drafted · lead
Enphase Energy
instance_of
c2 drafted · lead
Microinverter
requires
c3 drafted · lead
Enphase IQ Gateway
An IQ Gateway or IQ Combiner must be connected; system software periodically checks the link and microinverters may stop working without it.
c4 drafted · lead
Enphase IQ Cable
Conditions: IQ9N-HPB variant; AC port connects to IQ Cable or IQ Field Wireable Connector
c5 drafted · lead
Staubli MC4 PV connectors proposed
Conditions: IQ9N-HPB DC port must be mated with Staubli MC4 cable couplers evaluated by UL for intermateability
c6 drafted · lead
Enphase Installer App
Conditions: Used to scan microinverter serial numbers and connect to the IQ Gateway during installation
review note: support check: partial - The passage says to scan serial numbers with the Installer App and connect to the IQ Gateway, but it never states the app is required.
compatible_with
c7 drafted · lead
Enphase IQ8 Series Microinverters proposed
Scope: applications on-grid, backup
Conditions: IQ9N can be added to existing IQ8 systems on the same IQ Gateway and IQ System Controller, grid-tied or grid-forming with backup
c8 drafted · lead
Enphase IQ7 Series Microinverters (IQ7, IQ7+, IQ7X, IQ7A) proposed
Scope: applications on-grid, backup
Conditions: IQ9N can be added to existing IQ7 systems on the same IQ Gateway and IQ System Controller, grid-tied or with backup
c10 drafted · lead
Enphase IQ System Controller
Scope: applications backup
Conditions: Grid-forming (with backup) configurations; IQ System Controller, 2/3/3G/3M
c11 drafted · lead
Enphase IQ Battery
Conditions: Solar Plus Battery with IQ Battery 3/10, 3T/10T, 5P or 10C; combined PV continuous output limited to 150% of battery rated power (200% for IQ8 plus IQ9N-HPB mixed systems) unless PV shedding is used
incompatible_with
c9 drafted · lead
Enphase IQ7 Series Microinverters (IQ7, IQ7+, IQ7X, IQ7A) proposed
Conditions: Mixed systems including IQ7 Series do not support Sunlight Jump Start; IQ7 cannot be added to a site with existing IQ9N-HPB on the same gateway
review note: support check: partial - The passages say IQ7 cannot be added to a site with existing IQ9N-HPB and mixed systems lose Sunlight Jump Start, but they also say IQ9N can be added to IQ7 systems, so 'incompatible' overstates it.
implements
c12 verified · fact
Grid forming
Conditions: Sunlight Jump Start, only in systems of IQ8 Series and IQ9N microinverters with no IQ7 Series
verified by: review-workflowverified on: 2026-10-24
c13 verified · fact
DC ground-fault protection
Conditions: Class II double-insulated; requires PV modules with DC cables labeled PV wire or PV cable
verified by: review-workflowverified on: 2026-10-24
rated_power
c14 verified · fact
nominal 440 V-A
Conditions: Maximum continuous output power, IQ9N-A-DOM-US-HPB at 240 V
verified by: review-workflowverified on: 2026-10-24review note: support check: partial - The table shows 440 and 415 and the headers show 240 V and 208 V, but the power row's columns are not labeled by voltage, so the 440-to-240 V mapping is only implied by order.; possible conflict with c15 (same source; check the conditions)
c15 drafted · lead
nominal 415 V-A
Conditions: Maximum continuous output power, IQ9N-A-DOM-US-HPB at 208 V
review note: support check: partial - 415 is the second value and 208 V the second column, but the power row does not label the voltages, so the mapping is only implied by order.; possible conflict with c14 (same source; check the conditions)
rated_output_current
c16 drafted · lead
nominal 1.83 A
Conditions: Maximum continuous output current, IQ9N-A-DOM-US-HPB at 240 V
review note: possible conflict with c17 (same source; check the conditions)
c17 drafted · lead
nominal 2 A
Conditions: Maximum continuous output current, IQ9N-A-DOM-US-HPB at 208 V
review note: possible conflict with c16 (same source; check the conditions)
nominal_voltage
c18 drafted · lead
nominal 240 V
Conditions: IQ9N-A-DOM-US-HPB AC output configuration; grid voltage range 211-264 V
review note: support check: partial - The grid range 211-264 V is the first value in the row and 240 V is the first column, but the range columns are unlabeled and 240 V nominal is only implied.; possible conflict with c19 (same source; check the conditions)
c19 drafted · lead
nominal 208 V
Conditions: IQ9N-A-DOM-US-HPB AC output configuration; grid voltage range 183-229 V
review note: support check: partial - The 183-229 V range is the second value and 208 V the second column, but the range columns are unlabeled and 208 V nominal is only implied.; possible conflict with c18 (same source; check the conditions)
efficiency
c20 drafted · lead
nominal 97.8 PERCENT
Conditions: Peak efficiency, IQ9N-A-DOM-US-HPB at 240 V
review note: possible conflict with c21 (same source; check the conditions); possible conflict with c22 (same source; check the conditions); possible conflict with c23 (same source; check the conditions)
c21 drafted · lead
nominal 97.7 PERCENT
Conditions: Peak efficiency, IQ9N-A-DOM-US-HPB at 208 V
review note: possible conflict with c20 (same source; check the conditions); possible conflict with c22 (same source; check the conditions); possible conflict with c23 (same source; check the conditions)
c22 drafted · lead
nominal 97.5 PERCENT
Conditions: CEC weighted efficiency, IQ9N-A-DOM-US-HPB at 240 V
review note: possible conflict with c20 (same source; check the conditions); possible conflict with c21 (same source; check the conditions); possible conflict with c23 (same source; check the conditions)
c23 drafted · lead
nominal 97 PERCENT
Conditions: CEC weighted efficiency, IQ9N-A-DOM-US-HPB at 208 V
review note: possible conflict with c20 (same source; check the conditions); possible conflict with c21 (same source; check the conditions); possible conflict with c22 (same source; check the conditions)
Referenced by