The Enphase IQ Cable, earlier called the Q Cable, is a continuous 12 AWG, double-insulated, outdoor-rated AC cable with connectors built in at intervals so microinverters plug straight into it. It is used with IQ Series microinverters, including IQ6, IQ7 and IQ8 models. IQ Series microinverters need this cable and do not work with older Enphase cabling. The cable specification table lists a 600 V voltage rating. The connectors are rated for at most 20 A and a maximum 20 A OCPD, at ambient temperatures from -40 to 79 °C. Enphase recommends keeping voltage rise below 1% in the IQ Cable and below 2% across all of the AC wiring. Accessories include field-wireable connectors, raw cable with no connectors, cable clips, a disconnect tool, sealing caps for unused connectors and terminators for cut cable ends. Shock and fire hazards apply. Cap every unused connector, avoid nicking the conductors when you strip the sheath, and never install the terminator with power connected. Do not plug microinverters into cable that has been left disconnected in wet conditions, because doing so voids the Enphase warranty.
<!-- review notes
manufactured_byc1 drafted · lead Enphase Energy
sec=6.2 h=ad208eaf8f7esec=4.6 h=9760f9a695b9instance_ofContinuous 12 AWG, double-insulated, outdoor-rated cable with integrated microinverter connectors.
sec=6.2 h=ad208eaf8f7esec=4.6 h=9760f9a695b9sec=1.4.2 h=f467acc1106fcompatible_withc3 drafted · lead Enphase IQ6 Microinverters
IQ Series microinverters require the Q Cable; voltage rise tables cover IQ6+.
sec=h1 h=538631470d98sec=h39 h=c2244104b154c4 drafted · lead Enphase IQ7 Series Microinverters (IQ7, IQ7+, IQ7X, IQ7A) proposed
sec=4.6 h=9760f9a695b9sec=h40 h=f179311d6e30sec=h41 h=b58843104455review note: support check: partial - IQ7 raw cable tables exist for IQ7, 7+, 7X, 7A, implying compatibility, but only table titles are given with no explicit statement.
c5 drafted · lead Enphase IQ8 Series Microinverters proposed
sec=6.2 h=ad208eaf8f7esec=h42 h=2eb7e7364a1csec=h43 h=0705ef22119fsec=h45 h=bbff9a167a18review note: support check: partial - IQ8 raw cable table titles imply compatibility, but no explicit statement is given; the cable text only says microinverters generally.
has_hazardc6 drafted · lead Electric shock
Unused connectors must be covered with sealing caps; do not install the terminator with power connected.
sec=h14 h=c735af634041c7 drafted · lead Electrical fire
Damaged conductors when stripping the sheath or uncovered connectors pose fire risk.
sec=h14 h=c735af634041review note: support check: partial - Risk of fire is stated, and the stripping and uncovered-connector warnings appear, but the passage doesn't explicitly tie them to fire risk.; review: partial - The passage says 'Risk of fire' and warns about damaged conductors and uncovered connectors, but it never says those two conditions cause fire; it only says damaged wires may make the system not function properly.
rated_output_currentConditions: Maximum current of Enphase connectors on the cable assemblies; maximum OCPD also 20 A
sec=h17 h=bcd686e29a83verified by: review-workflowverified on: 2026-10-24
operating_temperaturec9 drafted · lead -40–79 DEG_C
Conditions: Ambient temperature range for Enphase connectors on the cable assemblies
sec=h17 h=bcd686e29a83