The Enphase IQ Cable, earlier called the Q Cable, is a continuous 12 AWG, double-insulated, outdoor-rated AC cable with connectors built in at intervals so microinverters plug straight into it. It is used with IQ Series microinverters, including IQ6, IQ7 and IQ8 models. IQ Series microinverters need this cable and do not work with older Enphase cabling. The cable specification table lists a 600 V voltage rating. The connectors are rated for at most 20 A and a maximum 20 A OCPD, at ambient temperatures from -40 to 79 °C. Enphase recommends keeping voltage rise below 1% in the IQ Cable and below 2% across all of the AC wiring. Accessories include field-wireable connectors, raw cable with no connectors, cable clips, a disconnect tool, sealing caps for unused connectors and terminators for cut cable ends. Shock and fire hazards apply. Cap every unused connector, avoid nicking the conductors when you strip the sheath, and never install the terminator with power connected. Do not plug microinverters into cable that has been left disconnected in wet conditions, because doing so voids the Enphase warranty.

<!-- review notes

Claims

manufactured_by

c1 drafted · lead Enphase Energy

instance_of

c2 drafted · lead AC cable

Continuous 12 AWG, double-insulated, outdoor-rated cable with integrated microinverter connectors.

compatible_with

c3 drafted · lead Enphase IQ6 Microinverters

IQ Series microinverters require the Q Cable; voltage rise tables cover IQ6+.

c4 drafted · lead Enphase IQ7 Series Microinverters (IQ7, IQ7+, IQ7X, IQ7A) proposed

review note: support check: partial - IQ7 raw cable tables exist for IQ7, 7+, 7X, 7A, implying compatibility, but only table titles are given with no explicit statement.

c5 drafted · lead Enphase IQ8 Series Microinverters proposed

review note: support check: partial - IQ8 raw cable table titles imply compatibility, but no explicit statement is given; the cable text only says microinverters generally.

has_hazard

c6 drafted · lead Electric shock

Unused connectors must be covered with sealing caps; do not install the terminator with power connected.

c7 drafted · lead Electrical fire

Damaged conductors when stripping the sheath or uncovered connectors pose fire risk.

review note: support check: partial - Risk of fire is stated, and the stripping and uncovered-connector warnings appear, but the passage doesn't explicitly tie them to fire risk.; review: partial - The passage says 'Risk of fire' and warns about damaged conductors and uncovered connectors, but it never says those two conditions cause fire; it only says damaged wires may make the system not function properly.

rated_output_current

c8 verified · fact ≤ 20 A

Conditions: Maximum current of Enphase connectors on the cable assemblies; maximum OCPD also 20 A

verified by: review-workflowverified on: 2026-10-24

operating_temperature

c9 drafted · lead -40–79 DEG_C

Conditions: Ambient temperature range for Enphase connectors on the cable assemblies