The I-V curve scan sweeps the PV input and records the current-voltage characteristic of the connected strings, so faults, damage or installation errors in the array can be found without a separate tracer. Sunny Tripower CORE1-US inverters measure one curve per MPPT input, so strings in parallel on that input show up as one combined curve, and the measured current cannot exceed the MPPT input current rating. On the CORE1-US, each scan briefly stops feed-in and runs the inverter at reduced power for about 20 seconds per MPPT input, and it can run at most 10 times per day unless the inverter is restarted. CORE1 results have over 200 data points per input, are stored until the next scan, can be saved to PDF, and show temperature and irradiance when the optional SMA Sensor Module is fitted. The function is listed for STP 33/50/62-US-41 from firmware 03.12.21.R, and the table lists firmware as not available for STP 50-US-40. On Canadian Solar CSI and Solis three-phase inverters, you set Start_V and Interval_V in the I/V Curve menu, then press ENT to start the scan. The display shows Scan OK when it finishes, and you then pick a string number to view its results. These CSI and Solis inverters record 60 data points per scan, and some models state a maximum scanning range of 100-1450V or 850-1450V. CPS inverters can start a scan over Modbus by writing 0xA801 to register 0x2B12. Reading the same register returns whether the scan is in progress, finished or failed. The Sunny Tripower X 12 to 25 datasheet lists I-V generator diagnostics as a feature.

<!-- review notes

Claims

setting_range

c1 drafted · lead 100–1400 V

Scope: products CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U

Conditions: Start_V, the start voltage of the I/V scan

c2 drafted · lead 100–1400 V

Scope: products Solis-3P(125-255)K-EHV-5G-US

Conditions: Start_V, the start voltage of the I/V scan

c3 drafted · lead 300–1000 V

Scope: products CSI-75/80/90/100K-T480GL02-U

Conditions: Start_V, the start voltage of the I/V scan

c4 verified · fact 850–1000 V

Scope: products CSI-125KTL-GS-E

Conditions: Start_V, the start voltage of the I/V scan

verified by: review-workflowverified on: 2026-10-24

c5 drafted · lead 1–100 V

Scope: products CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U, Solis-3P(125-255)K-EHV-5G-US, CSI-75/80/90/100K-T480GL02-U, CSI-125KTL-GS-E

Conditions: Interval_V, the scanning voltage step between data points

review note: support check: partial - Interval_V is 1-100V (001V-100V) in all four, but the passages tie them to products only loosely; the core range matches.

default_value

c6 drafted · lead nominal 100 V

Scope: products CSI-185K-T600GL02/03-U / CSI-255K-T800GL02/03-U

Conditions: Start_V value shown on the Set I/V Curve screen figure

Value shown in the manual's screen illustration; read as the displayed default.

c7 drafted · lead nominal 850 V

Scope: products CSI-125KTL-GS-E

Conditions: Start_V value shown on the Set I/V Curve screen figure

Value shown in the manual's screen illustration; read as the displayed default.