Solar Lattice

Concept

Islanding

ID
concept:islanding
IRI
https://solarlattice.org/kb/concept/islanding
Status
active
Also known as
unintentional island, intentional island, island
Category
Grid
Concept kind
electrical

Islanding is when a generator such as PV keeps powering load through utility lines after it has been cut off from the utility source. An island that was planned ahead to keep service running is an intentional island. One that was not planned is an unintentional island, and these are normally prohibited because they can damage equipment, lower power quality and endanger utility workers. A sustained unintentional island can form only if PV output and local load match closely in both real and reactive power when the upstream switch opens. If they do not match, voltage or frequency quickly drifts out of range and the inverter can detect the loss of mains. Detection methods can be passive, active (for example impedance detection or positive frequency feedback), or communications-based, such as direct transfer trip. Most commercial inverters combine impedance detection with positive feedback. Sandia suggests a sustained island is not physically possible when the total PV nameplate rating in the potential island is below 2/3 of the minimum daytime feeder load. Ride-through functions such as low-voltage ride-through make islands more likely to form, because low voltage can no longer be used to detect an island. Inverter islanding detection is designed to find balanced islands, not faults, so it should not be relied on as fault protection.

<!-- review notes

Claims

related_to

c1 verified · fact Anti-islanding

PV inverters carry island detection (anti-islanding) schemes to prevent unintentional islands.

verified by: review-workflowverified on: 2026-10-24

c2 drafted · lead Anti-islanding detection methods

Loss-of-mains detection is grouped into passive, active and communications-based methods.

c3 drafted · lead IEC 62116 proposed

Requires detection of an unintentional island and cessation of energization within 2 s.

c4 drafted · lead UL 1741 proposed

Islanding detection capability of compliant inverters is certified using an RLC test circuit.

c5 drafted · lead Cease to energize

c6 drafted · lead Area electric power system

c7 drafted · lead Automatic reclosing

Auto-reclose times longer than 2 s may be considered to coordinate with islanding detection.

c8 drafted · lead Low-voltage ride-through

Ride-through means low voltage can no longer serve for island detection, raising unintentional-island likelihood.

c9 verified · fact Backfeed from another source

An island can endanger utility workers and connected equipment.

verified by: review-workflowverified on: 2026-10-24

c10 drafted · lead Island operation

Storage controllers offer commands to intentionally transition into an off-grid islanded state.

review note: support check: partial - u14 and u21 show commands for an intentional transition to an off-grid state and islanding modes, but they do not name storage controllers or explicitly describe an islanded state concept.