Symptom

Reduced STC output power

ID
symptom:stc-power-drop
IRI
https://solarlattice.org/kb/symptom/stc-power-drop
Status
active
Also known as
peak power loss

The module puts out less power at standard test conditions than its nameplate says. This is found by flash testing or IV tracing a stabilised module, and it may also show up in monitoring data. If the module was below tolerance when new, the cause is a non-conforming power rating rather than degradation. Lab measurement uncertainty and the manufacturer's tolerance must be taken into account before calling it non-conforming. Light induced degradation lowers STC power along with Isc and Voc early in the system's life, with no visible defect. In some cases a patchwork pattern in EL images points to it. Delamination lowers Pmax mainly by cutting short-circuit current, because the air gaps reflect more light. It can be seen visually, and pulse thermography or scanning acoustic microscopy can detect it. Corrosion or abrasion of the glass or its anti-reflective coating cuts light transmission. The loss is usually a few percent and levels off over time. Look for it visually, and check reflectance after cleaning. First, compare stabilised flash-test or IV results and early production trends against the nameplate and the losses expected for that module technology. Then have an accredited lab confirm the underperformance before filing a warranty claim.

<!-- review notes

Claims

observed_as

c1 drafted · lead Pmax below rated value

Flash or IV test of a stabilised module gives STC power below the nameplate minimum after allowing for tolerance and lab uncertainty.

c2 drafted · lead Lowered Isc on IV curve

With delamination the Pmax loss comes mostly from lower Isc caused by extra reflection; LID also lowers Isc.

c3 drafted · lead Low open-circuit voltage

LID/LeTID lowers Voc together with STC power.

c4 drafted · lead Patchwork EL pattern

EL images becoming less uniform can sometimes point to ongoing light-induced degradation.

typical_power_loss

c5 drafted · lead ≤ 30 PERCENT

Conditions: Light induced degradation (light soaking), upper bound reported in one source

c6 disputed 1–3 PERCENT

Conditions: Boron-oxygen LID in c-Si modules, occurring within the first days of sun exposure

conflicts with: Reduced STC output power (c9)conflicts with: Reduced STC output power (c11)

c7 disputed ≤ 10 PERCENT

Conditions: LeTID in PERC-type modules at temperatures above 50 °C, developing over years and adding to LID loss

conflicts with: Reduced STC output power (c9)conflicts with: Reduced STC output power (c11)

c8 disputed 1–4 PERCENT

Conditions: LeTID in modules from manufacturers using in-line mitigation; varies by manufacturer

conflicts with: Reduced STC output power (c9)conflicts with: Reduced STC output power (c11)

c9 disputed nominal 20 PERCENT

Conditions: Field EFG-Si module with edge delamination and discoloration, first 3 years of deployment (reported as nearly 20% Pmax drop)

review note: possible conflict with c11 (same source; check the conditions)conflicts with: Reduced STC output power (c6)conflicts with: Reduced STC output power (c7)conflicts with: Reduced STC output power (c8)

c11 disputed nominal 11.5 PERCENT

Conditions: PV system after 12 years of exposure, loss attributed mostly to delamination at the cell/encapsulant interface

review note: possible conflict with c9 (same source; check the conditions)conflicts with: Reduced STC output power (c6)conflicts with: Reduced STC output power (c7)conflicts with: Reduced STC output power (c8)

current_drop

c10 drafted · lead nominal 5 PERCENT

Conditions: Same field EFG-Si module with delamination, Isc drop over the first 3 years (reported as about 5%)