Symptom
Reduced STC output power
- ID
symptom:stc-power-drop
- IRI
https://solarlattice.org/kb/symptom/stc-power-drop
- Status
- active
- Also known as
- peak power loss
The module puts out less power at standard test conditions than its nameplate says. This is found by flash testing or IV tracing a stabilised module, and it may also show up in monitoring data. If the module was below tolerance when new, the cause is a non-conforming power rating rather than degradation. Lab measurement uncertainty and the manufacturer's tolerance must be taken into account before calling it non-conforming. Light induced degradation lowers STC power along with Isc and Voc early in the system's life, with no visible defect. In some cases a patchwork pattern in EL images points to it. Delamination lowers Pmax mainly by cutting short-circuit current, because the air gaps reflect more light. It can be seen visually, and pulse thermography or scanning acoustic microscopy can detect it. Corrosion or abrasion of the glass or its anti-reflective coating cuts light transmission. The loss is usually a few percent and levels off over time. Look for it visually, and check reflectance after cleaning. First, compare stabilised flash-test or IV results and early production trends against the nameplate and the losses expected for that module technology. Then have an accredited lab confirm the underperformance before filing a warranty claim.
<!-- review notes
- sentence 1: support check: partial - The passages give STC power below nameplate with detection by IV and MON, but flash testing is not stated for this defect (only stabilisation and IV) and the statement's nameplate comparison is slightly looser.
- sentence 2: support check: partial - Lab uncertainty and manufacturer tolerance are required, but the passages don't state that a new module below tolerance is a non-conforming rating rather than degradation, beyond calling it not a real failure causing no degradation.
- sentence 4: support check: partial - Reflection-driven Isc loss and detection by pulse thermography and SAM are stated, but visual detection of delamination is not stated in the passages.
-->
Claims
observed_as
c1 drafted · lead
Pmax below rated value
Flash or IV test of a stabilised module gives STC power below the nameplate minimum after allowing for tolerance and lab uncertainty.
c2 drafted · lead
Lowered Isc on IV curve
With delamination the Pmax loss comes mostly from lower Isc caused by extra reflection; LID also lowers Isc.
c3 drafted · lead
Low open-circuit voltage
LID/LeTID lowers Voc together with STC power.
c4 drafted · lead
Patchwork EL pattern
EL images becoming less uniform can sometimes point to ongoing light-induced degradation.
typical_power_loss
c5 drafted · lead
≤ 30 PERCENT
Conditions: Light induced degradation (light soaking), upper bound reported in one source
c6 disputed
1–3 PERCENT
Conditions: Boron-oxygen LID in c-Si modules, occurring within the first days of sun exposure
conflicts with: Reduced STC output power (c9)conflicts with: Reduced STC output power (c11)
c7 disputed
≤ 10 PERCENT
Conditions: LeTID in PERC-type modules at temperatures above 50 °C, developing over years and adding to LID loss
conflicts with: Reduced STC output power (c9)conflicts with: Reduced STC output power (c11)
c8 disputed
1–4 PERCENT
Conditions: LeTID in modules from manufacturers using in-line mitigation; varies by manufacturer
conflicts with: Reduced STC output power (c9)conflicts with: Reduced STC output power (c11)
c9 disputed
nominal 20 PERCENT
Conditions: Field EFG-Si module with edge delamination and discoloration, first 3 years of deployment (reported as nearly 20% Pmax drop)
review note: possible conflict with c11 (same source; check the conditions)conflicts with: Reduced STC output power (c6)conflicts with: Reduced STC output power (c7)conflicts with: Reduced STC output power (c8)
c11 disputed
nominal 11.5 PERCENT
Conditions: PV system after 12 years of exposure, loss attributed mostly to delamination at the cell/encapsulant interface
review note: possible conflict with c9 (same source; check the conditions)conflicts with: Reduced STC output power (c6)conflicts with: Reduced STC output power (c7)conflicts with: Reduced STC output power (c8)
current_drop
c10 drafted · lead
nominal 5 PERCENT
Conditions: Same field EFG-Si module with delamination, Isc drop over the first 3 years (reported as about 5%)
Referenced by
Data