Solar Lattice

Product

Generac PV Link

ID
prod:generac-pv-link
IRI
https://solarlattice.org/kb/prod/generac-pv-link
Status
active
Also known as
PV Link, S2502, PV Link Optimizer
Category
MLPE
Make
generac
Product level
family

Generac PV Link is a non-isolated boost-type DC-DC optimizer. It raises the PV input voltage and feeds it onto REbus, Generac's regulated 380 VDC bus. It is rated for 2,500 W continuous, with a 420 VDC absolute maximum input, an 8 A continuous output current and a 99 percent peak efficiency. It uses power line communication on its DC output and includes ground fault protection, arc fault protection and rapid shutdown. Firmware updates arrive over the air. Connect it only to REbus-compatible equipment such as the PWRcell Inverter, never to a conventional PV inverter. Use Staubli MC4 connectors only. Never wire PV Links in series. You can parallel at most three on one home run. Units leave the factory disabled. Enable each one from the inverter control panel. If a PV Link shows offline, check its DC disconnect, its PLM channel setting, the REbus wiring and the REbus fuses. It is certified to UL 1741, UL 1699B and CSA C22.2 No. 107.1.

<!-- review notes

Claims

instance_of

c1 drafted · lead DC power optimizer

manufactured_by

c2 drafted · lead Generac

implements

c3 drafted · lead PV rapid shutdown

c4 verified · fact DC ground-fault protection

Ground fault detection and interruption (GFDI).

verified by: review-workflowverified on: 2026-10-24

c5 drafted · lead DC arc-fault protection

Arc fault detection and circuit interruption (AFCI).

c6 drafted · lead Remote firmware update

Over-the-air updates usually happen automatically; installers should confirm firmware is current.

uses_protocol

c7 drafted · lead Power line communication

Bidirectional PLC carried on the DC output to talk to inverters and other REbus devices.

certified_to

c8 drafted · lead UL 1741 proposed

c9 verified · fact UL 1699B proposed

verified by: review-workflowverified on: 2026-10-24

c10 drafted · lead CSA C22.2 No. 107.1 proposed

compatible_with

c11 drafted · lead Generac PWRcell Inverter (X7602, XVT076A03, XVT114G03)

Enabled, configured and monitored from the PWRcell Inverter control panel.

requires

c12 verified · fact Staubli MC4 PV connectors proposed

Field wiring must use Staubli MC4 connectors only.

verified by: review-workflowverified on: 2026-10-24

incompatible_with

c13 drafted · lead Grounded PV array

Modules that need positive or negative grounding would interfere with PLC communication.

rated_power

c14 drafted · lead nominal 2500 W

Conditions: continuous

max_input_voltage

c15 drafted · lead ≤ 420 V

Conditions: absolute maximum DC input voltage

max_input_current

c16 drafted · lead ≤ 18 A

Conditions: maximum input short-circuit current per PV Link

review note: support check: partial - The passage gives max input short-circuit current 18 A, but 'per PV Link' is not stated.

rated_output_current

c17 verified · fact ≤ 8 A

Conditions: maximum continuous output current per PV Link

verified by: review-workflowverified on: 2026-10-24

efficiency

c18 drafted · lead nominal 99 PERCENT

Conditions: peak efficiency

nominal_voltage

c19 drafted · lead nominal 380 V

Conditions: regulated DC output bus (REbus)

review note: possible conflict with c20 (same source; check the conditions)

c20 drafted · lead nominal 190 V

Conditions: REbus stated as plus/minus 190 VDC nominal regulated DC bus

review note: possible conflict with c19 (same source; check the conditions)