Generac PWRcell Inverter (X7602, XVT076A03, XVT114G03)
The Generac PWRcell Inverter is a family of inverters that includes the XVT076A03 (X7602) and XVT114G03 (X11402) models. On the DC side it connects to a REbus bus, which normally runs at 380 V dc and is rated from 360 to 420 V dc. The X7602 runs on a 240 V line-to-line grid (212 to 264 V) and the X11402 on a 208 V line-to-line grid (184 to 228 V). Both run at 120 V line-to-neutral, at 60 Hz. Peak efficiency is 97.3 percent for the X7602 and 97.7 percent for the X11402. CEC weighted efficiency is 96.5 and 97.5 percent. The enclosure is rated NEMA Type 3R. Cooling is by forced convection.
<!-- review notes
- sentence 2: support check: partial - Voltage values 360/380/420 min/nom/max are supported, but connection to a REbus bus on the DC side is only implied by the REbus voltage row. -->
Claims
manufactured_by
uses_protocol
c2 verified · fact REbus DC nanogrid proposed
Spec table lists a REbus DC voltage rating.
- Generac PWRcell Inverter X7602 installation manual
tbl=4.r21h=5562c27c261b
verified by: review-workflowverified on: 2026-10-24review note: support check: partial - Only a REbus voltage rating is shown; it implies REbus use but doesn't explicitly say the protocol is REbus DC nanogrid.
efficiency
c3 drafted · lead nominal 97.3 PERCENT
Conditions: Peak efficiency, XVT076A03 / X7602
- Generac PWRcell Inverter X7602 installation manual
tbl=4.r9h=a2e02f03f52c
review note: possible conflict with c4 (same source; check the conditions); possible conflict with c5 (same source; check the conditions); possible conflict with c6 (same source; check the conditions)
c4 drafted · lead nominal 97.7 PERCENT
Conditions: Peak efficiency, XVT114G03 / X11402
- Generac PWRcell Inverter X7602 installation manual
tbl=4.r9h=a2e02f03f52c
review note: possible conflict with c3 (same source; check the conditions); possible conflict with c5 (same source; check the conditions); possible conflict with c6 (same source; check the conditions)
c5 drafted · lead nominal 96.5 PERCENT
Conditions: CEC weighted efficiency, XVT076A03 / X7602
- Generac PWRcell Inverter X7602 installation manual
tbl=4.r12h=6e0f73055243
review note: possible conflict with c3 (same source; check the conditions); possible conflict with c4 (same source; check the conditions); possible conflict with c6 (same source; check the conditions)
c6 drafted · lead nominal 97.5 PERCENT
Conditions: CEC weighted efficiency, XVT114G03 / X11402
- Generac PWRcell Inverter X7602 installation manual
tbl=4.r12h=6e0f73055243
review note: possible conflict with c3 (same source; check the conditions); possible conflict with c4 (same source; check the conditions); possible conflict with c5 (same source; check the conditions)
nominal_voltage
c7 drafted · lead 212–264, nominal 240 V
Conditions: AC operating voltage range line-to-line, XVT076A03 / X7602 (min / nominal / max columns)
- Generac PWRcell Inverter X7602 installation manual
tbl=4.r27h=75d5d63616ce - Generac PWRcell Inverter X7602 installation manual
tbl=4.r20h=7867b92b2ca3
review note: support check: partial - Values 212/240/264 are min/nominal/max; nominal is 240, not a 212-264 range (range is operating).; possible conflict with c8 (same source; check the conditions); possible conflict with c10 (same source; check the conditions); possible conflict with c11 (same source; check the conditions)
c8 drafted · lead 106–132, nominal 120 V
Conditions: AC operating voltage range line-to-neutral, XVT076A03 / X7602
- Generac PWRcell Inverter X7602 installation manual
tbl=4.r26h=e8110039af21 - Generac PWRcell Inverter X7602 installation manual
tbl=4.r20h=7867b92b2ca3
review note: support check: partial - Values 106/120/132 are min/nominal/max; nominal is 120, not 106-132.; possible conflict with c7 (same source; check the conditions); possible conflict with c9 (same source; check the conditions); possible conflict with c11 (same source; check the conditions)
c9 drafted · lead 184–228, nominal 208 V
Conditions: AC operating output voltage range line-to-line, XVT114G03 / X11402
- Generac PWRcell Inverter X7602 installation manual
tbl=4.r29h=88eed1edc83f - Generac PWRcell Inverter X7602 installation manual
tbl=4.r20h=7867b92b2ca3
review note: support check: partial - Values 184/208/228 are min/nominal/max; nominal is 208, not 184-228.; possible conflict with c8 (same source; check the conditions); possible conflict with c10 (same source; check the conditions); possible conflict with c11 (same source; check the conditions)
c10 drafted · lead 106–132, nominal 120 V
Conditions: AC operating voltage range line-to-neutral, XVT114G03 / X11402
- Generac PWRcell Inverter X7602 installation manual
tbl=4.r28h=dae7d1143cd0 - Generac PWRcell Inverter X7602 installation manual
tbl=4.r20h=7867b92b2ca3
review note: support check: partial - Values 106/120/132 are min/nominal/max; nominal is 120, not 106-132.; possible conflict with c7 (same source; check the conditions); possible conflict with c9 (same source; check the conditions); possible conflict with c11 (same source; check the conditions)
c11 drafted · lead 360–420, nominal 380 V
Conditions: REbus DC bus voltage
- Generac PWRcell Inverter X7602 installation manual
tbl=4.r21h=5562c27c261b - Generac PWRcell Inverter X7602 installation manual
tbl=4.r20h=7867b92b2ca3
review note: support check: partial - 360/380/420 are min/nominal/max; nominal is 380, not 360-420.; possible conflict with c7 (same source; check the conditions); possible conflict with c8 (same source; check the conditions); possible conflict with c9 (same source; check the conditions); possible conflict with c10 (same source; check the conditions)
frequency
c12 drafted · lead nominal 60 HZ
Conditions: Normal AC output frequency, all models
- Generac PWRcell Inverter X7602 installation manual
tbl=4.r6h=a5eca578edde
operating_temperature
c13 drafted · lead -20–50 DEG_C
Conditions: Full-power operating ambient temperature range
- Generac PWRcell Inverter X7602 installation manual
tbl=4.r36h=791be3168eba
Referenced by
- Permission to operate
related_toc4 - PV hazard control
related_toc8 - Generac PWRcell Inverter 0X7700
applies_toc6 - Generac PWRcell Inverter 0X7701
applies_toc5 - Generac PWRcell Inverter 0X7702
applies_toc5 - Generac PWRcell Inverter 0X7703
applies_toc6 - Generac PWRcell Inverter 0X7704
applies_toc5 - Generac PWRcell Inverter 0X7705
applies_toc5 - Generac PWRcell Inverter 0X7706
applies_toc5 - Generac PWRcell Inverter 0X7707
applies_toc5 - Generac PWRcell Inverter 0X7708
applies_toc5 - Generac PWRcell Inverter 0X7709
applies_toc4 - Generac PWRcell Inverter 0X770A
applies_toc5 - Generac PWRcell Inverter 0X770B
applies_toc4 - Generac PWRcell Inverter 0X770C
applies_toc5 - Generac PWRcell Inverter 0X770D
applies_toc5 - Generac PWRcell Inverter 0X7720
applies_toc6 - Generac PWRcell Inverter 0X7721
applies_toc4 - Generac PWRcell Inverter 0X7722
applies_toc5 - Generac PWRcell Inverter 0X7724
applies_toc5 - Generac PWRcell Inverter 0X7726
applies_toc7 - Generac PWRcell Inverter 0X7727
applies_toc6 - Generac PWRcell Inverter 0x8061
applies_toc5 - Generac PWRcell Inverter 0x8062
applies_toc5 - Generac PWRcell Inverter 0x8063
applies_toc5 - Generac PWRcell Inverter 0x8064
applies_toc5 - Generac PWRcell Inverter 0x8065
applies_toc5 - Generac PWRcell Inverter 0x8066
applies_toc5 - Generac PWRcell Inverter 0x8067
applies_toc5 - Generac PWRcell Inverter 0x8069
applies_toc5 - Generac PWRcell Inverter 0x806A
applies_toc5 - Generac PWRcell Inverter 0x806B
applies_toc5 - Generac PWRcell Inverter 0x806C
applies_toc5 - Generac PWRcell Inverter 0x806D
applies_toc5 - Generac PWRcell Inverter 0x806E
applies_toc5 - Generac PWRcell Inverter 0x806F
applies_toc5 - Generac PWRcell Inverter 0x8070
applies_toc4 - Generac PV Link
compatible_withc11 - Generac PWRcell Battery
compatible_withc3 - Generac PWRmanager
compatible_withc1 - Generac SnapRS
compatible_withc4