Product
Solectria PVI 3800-7600TL
- ID
prod:yaskawa-solectria-pvi-3800-7600tl
- IRI
https://solarlattice.org/kb/prod/yaskawa-solectria-pvi-3800-7600tl
- Status
- active
- Also known as
- PVI 3800 7600 TL
- Category
- Inverters
- Make
- yaskawa-solectria
- Product level
- family
The Solectria PVI 3800-7600TL is a family of transformerless, utility-interactive inverters for permanent connection. It comes in four models: PVI 3800TL, 5200TL, 6600TL and 7600TL. Nominal AC output runs from 3800 W to 7600 W. At 208 V the 3800TL is limited to 3300 W and the 7600TL to 6600 W. All models accept up to 600 V DC system voltage, with a full-power MPP range of 200 to 500 V. The 3800TL has one MPP tracker and the larger models have two. Maximum efficiency is 98.0 percent, and CEC efficiency is 97.5 percent at both 208 V and 240 V. The units have an internal DC disconnect, screw terminals for AC and DC wiring, convection cooling and an RS-485 communication interface. They are listed to UL 1741 and CSA 22.2 No. 107-01, have UL 1998 software approval, and meet IEEE 1547 and 1547.1 for anti-islanding. Arc-fault protection is to UL 1699B Type 1, and isolation monitoring is to NEC 690.35. EMC compliance covers FCC part 15 A and B and ICES-003. The standard warranty is 10 years.
Claims
manufactured_by
c1 drafted · lead
Yaskawa Solectria Solar
review note: support check: partial - Passage shows garbled 'VYASA SOLECTRIA SOLAR' with the model names; maker identity is implied but not clearly stated as Yaskawa.
instance_of
c2 drafted · lead
Inverter
Listed as a transformerless utility-interactive inverter, permanently connected.
uses_protocol
c3 drafted · lead
RS-485
RS-485 is the communication interface on all four models.
certified_to
c4 drafted · lead
UL 1741 proposed
Listed under safety standards.
c5 drafted · lead
UL 1998 proposed
Software approval.
c6 drafted · lead
IEEE 1547 proposed
Covers unintentional islanding protection.
c7 drafted · lead
IEEE 1547.1 proposed
Covers unintentional islanding protection; the source gives no edition.
c8 drafted · lead
UL 1699B proposed
AFCI, Type 1.
c9 drafted · lead
FCC Part 15 proposed
EMC: FCC part 15 A and B.
c10 drafted · lead
ICES-003 proposed
EMC.
implements
c11 drafted · lead
Anti-islanding
c12 drafted · lead
DC arc-fault protection
c13 drafted · lead
Insulation monitoring
Isolation Monitor Interrupt (IMI).
c14 drafted · lead
Maximum power point tracking
PVI 3800TL has 1 MPP tracker; the 5200TL, 6600TL and 7600TL have 2.
rated_power
c15 verified · fact
nominal 3800 W
Conditions: PVI 3800TL nominal AC output power
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c16 (same source; check the conditions); possible conflict with c17 (same source; check the conditions); possible conflict with c18 (same source; check the conditions); possible conflict with c19 (same source; check the conditions)
c16 drafted · lead
nominal 5200 W
Conditions: PVI 5200TL nominal AC output power
review note: possible conflict with c15 (same source; check the conditions); possible conflict with c17 (same source; check the conditions); possible conflict with c18 (same source; check the conditions); possible conflict with c19 (same source; check the conditions)
c17 drafted · lead
nominal 6600 W
Conditions: PVI 6600TL nominal AC output power
review note: possible conflict with c15 (same source; check the conditions); possible conflict with c16 (same source; check the conditions); possible conflict with c18 (same source; check the conditions); possible conflict with c19 (same source; check the conditions)
c18 drafted · lead
nominal 7600 W
Conditions: PVI 7600TL nominal AC output power
review note: possible conflict with c15 (same source; check the conditions); possible conflict with c16 (same source; check the conditions); possible conflict with c17 (same source; check the conditions); possible conflict with c19 (same source; check the conditions); possible conflict with c20 (same source; check the conditions)
c19 verified · fact
≤ 3300 W
Conditions: PVI 3800TL maximum AC power at 208 V
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c15 (same source; check the conditions); possible conflict with c16 (same source; check the conditions); possible conflict with c17 (same source; check the conditions); possible conflict with c18 (same source; check the conditions)
c20 drafted · lead
≤ 6600 W
Conditions: PVI 7600TL maximum AC power at 208 V
review note: possible conflict with c18 (same source; check the conditions)
max_input_voltage
c21 verified · fact
≤ 600 V
Conditions: Maximum DC system voltage, all models
verified by: review-workflowverified on: 2026-10-24
mppt_voltage_range
c22 drafted · lead
200–500 V
Conditions: Full-power MPP range, all models
efficiency
c23 drafted · lead
nominal 98 PERCENT
Conditions: Maximum efficiency, all models
review note: possible conflict with c24 (same source; check the conditions)
c24 drafted · lead
nominal 97.5 PERCENT
Conditions: CEC efficiency at 208 V and 240 V, all models
review note: possible conflict with c23 (same source; check the conditions)
warranty_term
c25 verified · fact
nominal 10 YR
Conditions: Standard warranty, all models
verified by: review-workflowverified on: 2026-10-24
Referenced by
Data