- 44002492947-rhi-3-6-k-48es-5g-and-s5-eh1p-3-6-k-self-use-setup
sec=fronth=f0fdd1c1925d - 44002492966-solis-hybrid-inverter-s5-eh1p-3-6-k-l-or-rhi-3-6-k-48es-5g-and-puredrive-battery-installation
sec=fronth=45b6ab0b365d
Solis RHI-48ES-5G hybrid
The Solis RHI-(3-6)K-48ES-5G is a single-phase hybrid inverter family made by Solis. Its most common setup is self-use storage mode. In that mode you can turn on grid charging, and you should turn off backup if the site does not use it. It has been installed with Puredrive batteries, using three Puredrive units in the example installation. For hybrid control, export limiting and consumption monitoring, use only meters and CTs on Solis's list: the Eastron SDM120CTM with an ESCT-TA16 CT, the Eastron SDM630MCT, or the Acrel ACR10R-16DTE and ACR10R-16DTE4 with XH-SCT-T16/120 CTs. Solis will not support a site that uses a meter or CT that is not on its list. Local DSP and HMI firmware updates are done with the Solis update stick in the green 4-pin COM port. The HMI file for this family is named HMI_WIFI.bin. Before a local update, unplug the communication cables and set the inverter address to 1. Solis sends update sticks only to installers.
<!-- review notes
- sentence 4: support check: partial - The listed meters and CTs match, but the guide also lists others (such as SDM630MCT with other CTs and the Solis CT) and the statement narrows the list. -->
Claims
manufactured_by
instance_of
Described as a single-phase hybrid inverter.
compatible_with
c3 drafted · lead Hybrid inverter system
c9 drafted · lead Puredrive battery proposed
Installation video shows the inverter with three Puredrive batteries.
c10 drafted · lead Eastron SDM120CTM meter proposed
Single-phase meter for hybrid control logic, export limiting and consumption monitoring.
- 44002687170-solis-meter-and-ct-compatibility-guide
sec=h1h=0caa9c940137
c11 drafted · lead Eastron ESCT-TA16 CT proposed
ESCT-TA16 100A/100mA CT used together with the Eastron SDM120CTM meter.
- 44002687170-solis-meter-and-ct-compatibility-guide
sec=h1h=0caa9c940137
c12 drafted · lead Eastron SDM630 meter proposed
SDM630MCT 40mA three-phase variant; the single-phase inverter connects on phase L1.
- 44002687170-solis-meter-and-ct-compatibility-guide
sec=h1h=0caa9c940137
c13 drafted · lead Acrel ACR10R-16DTE meter proposed
- 44002687170-solis-meter-and-ct-compatibility-guide
sec=h1h=0caa9c940137
c14 drafted · lead Acrel ACR10R-16DTE4 meter proposed
Three-phase meter; the inverter connects on phase A.
- 44002687170-solis-meter-and-ct-compatibility-guide
sec=h1h=0caa9c940137
c15 drafted · lead Acrel XH-SCT-T16/120 CT proposed
CT used with Acrel meters.
- 44002687170-solis-meter-and-ct-compatibility-guide
sec=h1h=0caa9c940137
implements
c4 drafted · lead Self-consumption optimization
Scope: applications self-consumption
Self-use storage mode, described as the most common configuration.
- 44002492947-rhi-3-6-k-48es-5g-and-s5-eh1p-3-6-k-self-use-setup
sec=h1h=e7a8d245db57
c5 drafted · lead Battery charging from the grid
Grid charging can be enabled during self-use setup.
- 44002492947-rhi-3-6-k-48es-5g-and-s5-eh1p-3-6-k-self-use-setup
sec=h1h=e7a8d245db57
c6 drafted · lead Backup power
Setup guidance says to disable backup if it is not used.
- 44002492947-rhi-3-6-k-48es-5g-and-s5-eh1p-3-6-k-self-use-setup
sec=h1h=e7a8d245db57
review note: support check: partial - The passage only says to disable backup if it is not in use, which implies backup exists but does not state backup power support outright.
c7 drafted · lead Export limitation
Conditions: With a compatible Solis-listed meter installed
- 44002687170-solis-meter-and-ct-compatibility-guide
sec=h1h=0caa9c940137
c8 verified · fact Consumption metering proposed
Conditions: With a compatible Solis-listed meter or CT installed
- 44002687170-solis-meter-and-ct-compatibility-guide
sec=h1h=0caa9c940137
verified by: review-workflowverified on: 2026-10-24
requires
c16 drafted · lead Solis firmware update stick proposed
Conditions: Local DSP or HMI firmware update through the 4-pin green COM port
- 44002485763-procedure-for-local-hmi-dsp-update
sec=h1h=7bf9db597d18
Conditions: Solis sends update sticks only to installers, not to system owners
- 44002485763-procedure-for-local-hmi-dsp-update
sec=h1h=7bf9db597d18
review note: support check: partial - Update sticks are sent only to installers, but the passage does not say the model requires an installer role.