Solar Lattice

Product

Solis RHI-48ES-5G hybrid

ID
prod:solis-rhi-48es-5g
IRI
https://solarlattice.org/kb/prod/solis-rhi-48es-5g
Status
active
Also known as
RHI-48ES-5G, RHI-3K-48ES-5G, RHI-K-48ES-5G, Solis Single Phase Hybrid inverter
Category
Inverters
Make
solis
Product level
family

The Solis RHI-(3-6)K-48ES-5G is a single-phase hybrid inverter family made by Solis. Its most common setup is self-use storage mode. In that mode you can turn on grid charging, and you should turn off backup if the site does not use it. It has been installed with Puredrive batteries, using three Puredrive units in the example installation. For hybrid control, export limiting and consumption monitoring, use only meters and CTs on Solis's list: the Eastron SDM120CTM with an ESCT-TA16 CT, the Eastron SDM630MCT, or the Acrel ACR10R-16DTE and ACR10R-16DTE4 with XH-SCT-T16/120 CTs. Solis will not support a site that uses a meter or CT that is not on its list. Local DSP and HMI firmware updates are done with the Solis update stick in the green 4-pin COM port. The HMI file for this family is named HMI_WIFI.bin. Before a local update, unplug the communication cables and set the inverter address to 1. Solis sends update sticks only to installers.

<!-- review notes

Claims

manufactured_by

c1 drafted · lead Solis

instance_of

c2 drafted · lead Inverter

Described as a single-phase hybrid inverter.

compatible_with

c3 drafted · lead Hybrid inverter system

c9 drafted · lead Puredrive battery proposed

Installation video shows the inverter with three Puredrive batteries.

c10 drafted · lead Eastron SDM120CTM meter proposed

Single-phase meter for hybrid control logic, export limiting and consumption monitoring.

c11 drafted · lead Eastron ESCT-TA16 CT proposed

ESCT-TA16 100A/100mA CT used together with the Eastron SDM120CTM meter.

c12 drafted · lead Eastron SDM630 meter proposed

SDM630MCT 40mA three-phase variant; the single-phase inverter connects on phase L1.

c13 drafted · lead Acrel ACR10R-16DTE meter proposed

c14 drafted · lead Acrel ACR10R-16DTE4 meter proposed

Three-phase meter; the inverter connects on phase A.

c15 drafted · lead Acrel XH-SCT-T16/120 CT proposed

CT used with Acrel meters.

implements

c4 drafted · lead Self-consumption optimization

Scope: applications self-consumption

Self-use storage mode, described as the most common configuration.

c5 drafted · lead Battery charging from the grid

Grid charging can be enabled during self-use setup.

c6 drafted · lead Backup power

Setup guidance says to disable backup if it is not used.

review note: support check: partial - The passage only says to disable backup if it is not in use, which implies backup exists but does not state backup power support outright.

c7 drafted · lead Export limitation

Conditions: With a compatible Solis-listed meter installed

c8 verified · fact Consumption metering proposed

Conditions: With a compatible Solis-listed meter or CT installed

verified by: review-workflowverified on: 2026-10-24

requires

c16 drafted · lead Solis firmware update stick proposed

Conditions: Local DSP or HMI firmware update through the 4-pin green COM port

c17 drafted · lead Installer

Conditions: Solis sends update sticks only to installers, not to system owners

review note: support check: partial - Update sticks are sent only to installers, but the passage does not say the model requires an installer role.

Data