Product
Sunny Tripower 8000-17000TL-10
- ID
prod:sma-stp-tl-10
- IRI
https://solarlattice.org/kb/prod/sma-stp-tl-10
- Status
- active
- Also known as
- STP 8000-17000TL-10, STP xx000TL-10, STP TL-10, STP8-17000TL-10
- Category
- Inverters
- Make
- sma
- Product level
- family
The Sunny Tripower 8000-17000TL-10 is an SMA three-phase PV inverter family made up of the STP 8000TL-10, 10000TL-10, 12000TL-10, 15000TL-10 and 17000TL-10; SMA now files its manuals as archived. These inverters contain an electronic string fuse that stops dangerous reverse currents in the PV array. It is a separate part from the Electronic Solar Switch (ESS) handle, which is used to disconnect the DC strings without load. If a string is connected with reversed polarity, strings with different module counts are mixed, or a string is defective, the inverter short-circuits the PV array and beeps. While it beeps, do not pull the DC connectors or the ESS, because this risks an arc or a fire. Wait until it goes quiet after dark before you disconnect and fix the string. Event 82, 8201 or 8203 with a red LED, a beep and the message that the device is short-circuited can come before event 7401 (varistor faulty). On existing plants, check the varistors and their thermal fuses and replace them if needed. The STP 17000TL-10 is listed as an inverter with a multifunction relay that communicates over Speedwire. SMA sells spare-part sets for this family: a power assembly, an AC assembly and a DC filter assembly. A DC surge protection device retrofit manual uses this family as its example installation.
<!-- review notes
- sentence 1: support check: partial - Passages list the five models as archived manuals from SMA, but 'three-phase' is not stated.
- sentence 6: support check: partial - Spare-part sets for power, AC and DC filter assemblies and an SPD figure using the STP XX000TL-10 family are present, but the passages don't say SMA sells them or that it is a retrofit manual.
- sentence 1: review: partial - The five models and their archived manuals are in the passages, but nothing calls the family three-phase.
-->
Claims
manufactured_by
c1 drafted · lead
SMA
review note: support check: partial - Passages are SMA service articles listing Sunny Tripower 8000-17000TL-10 manuals, implying SMA makes it, but they never explicitly say 'made by SMA'.
instance_of
c2 verified · fact
Inverter
- 278405
tbl=39.r14 h=5e7a773094cc
verified by: review-workflowverified on: 2026-10-24
uses_protocol
c3 drafted · lead
SMA Speedwire
Scope: products Sunny Tripower 8000-17000TL-10
Listed for the STP 17000TL-10 as an inverter with multifunction relay, communication standard Speedwire.
- 278405
tbl=39.r14 h=5e7a773094cc
has_hazard
c4 drafted · lead
DC arc flash
Conditions: While the electronic string fuse has short-circuited the PV array and the inverter is beeping
Do not pull the DC connectors or the ESS while the inverter beeps; risk of an electric arc.
c5 drafted · lead
Electrical fire
Conditions: If the ESS is pulled during a short-circuit/reverse-current event
The whole reverse current would then flow through the faulty string and could start a fire.
c6 drafted · lead
Arc from disconnecting under load
Conditions: Disconnecting DC connectors while the inverter beeps
Disconnect only once beeping stops after dark.