- Also known as
- SCH 100 125 KTL, CPS 100 125 kW, Chint/100 125 kW, SCH100KTL-DO/US-600, SCH125KTL-DO/US-600, SCH100KTL-DO/US-480
- Category
- Inverters
- Make
- chint
- Product level
- family
The CPS SCH100-125KTL family consists of three-phase string inverters from CHINT Power Systems. It covers the SCH100KTL-DO/US-600, SCH125KTL-DO/US-600 and SCH100KTL-DO/US-480 models. The rated AC output is 100 kW or 125 kW, depending on the model. The 600 V models output 600 Vac and the 480 V model outputs 480 Vac. All models accept up to 1500 VDC on the DC input and a maximum PV input current of 275 A. Through the FlexOM gateway card, the inverter communicates over standard Modbus RS485, SunSpec Modbus and HTTPS/XML for third-party monitoring and control. Remote diagnostics and firmware upgrades are listed as standard with the CPS Flex Gateway. The CommErr alarm means internal communication failed, which can be caused by poorly seated internal communication terminal blocks. The ExtFanErr alarm points to a blocked fan, a fan at the end of its service life, or a poor fan socket contact.
<!-- review notes
- sentence 1: support check: partial - Three models are listed, but three-phase string inverter type isn't stated and the family naming is only implied.
- sentence 5: support check: partial - The row is a merged label/value that lists standard with CPS Flex Gateway, but the values shown are certifications, so the remote diagnostics claim is only implied.
- sentence 1: review: partial - The three models and the CHINT maker appear in the passages, but 'three-phase string inverters' and the family name are not stated.
-->
Claims
manufactured_by
c1 drafted · lead
CHINT POWER SYSTEMS
review note: support check: partial - Evidence names CHINT Power Systems America but doesn't tie the SCH100-125KTL-DO/US-600 model to it explicitly.
max_input_voltage
c2 drafted · lead
nominal 1500 V
Conditions: Maximum DC input voltage, all three models
max_input_current
c3 drafted · lead
nominal 275 A
Conditions: Maximum PV input current (Isc x 1.25) per inverter, all three models
efficiency
c4 drafted · lead
nominal 99 PERCENT
Conditions: Maximum efficiency as stated in the product overview features list
review note: possible conflict with c5 (same source; check the conditions)
c5 drafted · lead
nominal 98.5 PERCENT
Conditions: CEC efficiency as stated in the product overview features list
review note: possible conflict with c4 (same source; check the conditions)
uses_protocol
c6 drafted · lead
RS-485
Standard Modbus over RS485 via FlexOM gateway card
c7 drafted · lead
SunSpec Modbus
Via FlexOM gateway card
requires
c8 drafted · lead
CPS FlexOM Gateway
Modbus, SunSpec and HTTPS/XML communications are provided through the FlexOM gateway card
implements
c9 drafted · lead
Remote firmware update
Listed as standard with the CPS Flex Gateway
review note: support check: partial - Row lists remote diagnostics/firmware upgrade as standard with CPS Flex Gateway, but the garbled row doesn't cleanly state firmware update support; the gateway name also differs slightly.
certified_to
c10 drafted · lead
UL 1741 SA proposed
c11 drafted · lead
UL 1741 SB proposed
c12 drafted · lead
IEEE 1547-2018 proposed
c13 drafted · lead
FCC Part 15 proposed