Solar Lattice

Product

CPS SCH100-125KTL-DO/US-600

ID
prod:chint-sch-100-125ktl
IRI
https://solarlattice.org/kb/prod/chint-sch-100-125ktl
Status
active
Also known as
SCH 100 125 KTL, CPS 100 125 kW, Chint/100 125 kW, SCH100KTL-DO/US-600, SCH125KTL-DO/US-600, SCH100KTL-DO/US-480
Category
Inverters
Make
chint
Product level
family

The CPS SCH100-125KTL family consists of three-phase string inverters from CHINT Power Systems. It covers the SCH100KTL-DO/US-600, SCH125KTL-DO/US-600 and SCH100KTL-DO/US-480 models. The rated AC output is 100 kW or 125 kW, depending on the model. The 600 V models output 600 Vac and the 480 V model outputs 480 Vac. All models accept up to 1500 VDC on the DC input and a maximum PV input current of 275 A. Through the FlexOM gateway card, the inverter communicates over standard Modbus RS485, SunSpec Modbus and HTTPS/XML for third-party monitoring and control. Remote diagnostics and firmware upgrades are listed as standard with the CPS Flex Gateway. The CommErr alarm means internal communication failed, which can be caused by poorly seated internal communication terminal blocks. The ExtFanErr alarm points to a blocked fan, a fan at the end of its service life, or a poor fan socket contact.

<!-- review notes

Claims

manufactured_by

c1 drafted · lead CHINT POWER SYSTEMS

review note: support check: partial - Evidence names CHINT Power Systems America but doesn't tie the SCH100-125KTL-DO/US-600 model to it explicitly.

max_input_voltage

c2 drafted · lead nominal 1500 V

Conditions: Maximum DC input voltage, all three models

max_input_current

c3 drafted · lead nominal 275 A

Conditions: Maximum PV input current (Isc x 1.25) per inverter, all three models

efficiency

c4 drafted · lead nominal 99 PERCENT

Conditions: Maximum efficiency as stated in the product overview features list

review note: possible conflict with c5 (same source; check the conditions)

c5 drafted · lead nominal 98.5 PERCENT

Conditions: CEC efficiency as stated in the product overview features list

review note: possible conflict with c4 (same source; check the conditions)

uses_protocol

c6 drafted · lead RS-485

Standard Modbus over RS485 via FlexOM gateway card

c7 drafted · lead SunSpec Modbus

Via FlexOM gateway card

requires

c8 drafted · lead CPS FlexOM Gateway

Modbus, SunSpec and HTTPS/XML communications are provided through the FlexOM gateway card

implements

c9 drafted · lead Remote firmware update

Listed as standard with the CPS Flex Gateway

review note: support check: partial - Row lists remote diagnostics/firmware upgrade as standard with CPS Flex Gateway, but the garbled row doesn't cleanly state firmware update support; the gateway name also differs slightly.

certified_to

c10 drafted · lead UL 1741 SA proposed

c11 drafted · lead UL 1741 SB proposed

c12 drafted · lead IEEE 1547-2018 proposed

c13 drafted · lead FCC Part 15 proposed

Referenced by