c1 drafted · lead Canadian Solar
The manual is published by CSI Solar Co., Ltd.
- CSI Installation Manual 25-40K T480GL01-UB LSW USA V1.1
sec=1.1h=c925f9649a6a
The CSI-25/30/36/40K-T480GL01-UB is a Canadian Solar family of four three-phase grid-tied string inverters that turn PV array DC power into AC power for local loads and the utility grid. The four models are rated at 25, 30, 36 and 40 kW, all on a 480 V grid connection. The 25K model has a maximum output current of 30.1 A and the 30K model has 36.1 A. The datasheet lists a maximum DC input voltage of 1000 V for the 36K model. Peak efficiency is listed at 98.6 percent. The CEC weighted efficiency is 98.3 percent for the 30K and 40K models. The 40K model is specified for a 60 Hz grid and operates between 59.5 and 60.5 Hz. Every model has integrated DC arc-fault circuit protection (AFCI).
<!-- review notes
manufactured_byc1 drafted · lead Canadian Solar
The manual is published by CSI Solar Co., Ltd.
sec=1.1 h=c925f9649a6ainstance_ofThree-phase inverter that converts PV DC power to AC power for local loads and the grid
sec=1.1 h=c925f9649a6acompatible_withc3 drafted · lead Grid-tied PV without storage
Scope: applications on-grid
sec=h1 h=64c940e7f033sec=1.1 h=c925f9649a6areview note: support check: partial - Feeding the grid is stated and the manual is titled grid-tied, but no storage exclusion is stated.
implementsc4 drafted · lead DC arc-fault protection
Integrated AFCI listed for all four models
tbl=13.r34 h=2f3149825b0ftbl=15.r34 h=94b574fc26catbl=17.r34 h=2b1fa73a0fd3tbl=19.r34 h=147b3c872101rated_powerc5 drafted · lead nominal 25 KiloW
Conditions: CSI-25K-T480GL01-UB at 480 V
tbl=7 h=c4d2afa6924ereview note: possible conflict with c6 (same source; check the conditions); possible conflict with c7 (same source; check the conditions); possible conflict with c8 (same source; check the conditions)
c6 drafted · lead nominal 30 KiloW
Conditions: CSI-30K-T480GL01-UB at 480 V
tbl=7 h=c4d2afa6924ereview note: possible conflict with c5 (same source; check the conditions); possible conflict with c7 (same source; check the conditions); possible conflict with c8 (same source; check the conditions)
c7 verified · fact nominal 36 KiloW
Conditions: CSI-36K-T480GL01-UB at 480 V
tbl=7 h=c4d2afa6924everified by: review-workflowverified on: 2026-10-24review note: possible conflict with c5 (same source; check the conditions); possible conflict with c6 (same source; check the conditions); possible conflict with c8 (same source; check the conditions)
c8 verified · fact nominal 40 KiloW
Conditions: CSI-40K-T480GL01-UB at 480 V
tbl=7 h=c4d2afa6924everified by: review-workflowverified on: 2026-10-24review note: possible conflict with c5 (same source; check the conditions); possible conflict with c6 (same source; check the conditions); possible conflict with c7 (same source; check the conditions)
nominal_voltagec9 drafted · lead nominal 480 V
Conditions: Nominal AC grid voltage, all models
tbl=7 h=c4d2afa6924etbl=19.r15 h=6a6fe6492084rated_output_currentc10 drafted · lead nominal 30.1 A
Conditions: Maximum AC output current, CSI-25K-T480GL01-UB
tbl=13.r20 h=496ffa3a5f47review note: possible conflict with c11 (same source; check the conditions)
c11 drafted · lead nominal 36.1 A
Conditions: Maximum AC output current, CSI-30K-T480GL01-UB
tbl=15.r20 h=79badb1eacaareview note: possible conflict with c10 (same source; check the conditions)
max_input_voltagec12 drafted · lead nominal 1000 V
Conditions: Maximum DC input voltage, CSI-36K-T480GL01-UB datasheet
tbl=17.r3 h=f9f0380d621cefficiencyc13 drafted · lead nominal 98.6 PERCENT
Conditions: Peak efficiency, 25K, 30K, 36K and 40K models
tbl=13.r30 h=1dfab83ccd8etbl=15.r30 h=1cded50f41fdtbl=17.r30 h=6e18e99ac491tbl=19.r30 h=decb015816ffreview note: possible conflict with c14 (same source; check the conditions)
c14 drafted · lead nominal 98.3 PERCENT
Conditions: CEC weighted efficiency, 30K and 40K models
tbl=15.r31 h=48590b3a9650tbl=19.r31 h=7cd0d43ada25review note: possible conflict with c13 (same source; check the conditions)
frequencyc15 drafted · lead nominal 60 HZ
Conditions: Nominal grid frequency, CSI-40K-T480GL01-UB
tbl=19.r17 h=390859269b0ec16 drafted · lead 59.5–60.5 HZ
Conditions: Operating frequency range, CSI-40K-T480GL01-UB
tbl=19.r18 h=40800b1e1912operating_temperaturec17 drafted · lead -25–60 DEG_C
Conditions: Ambient operating temperature range, 30K, 36K and 40K models
tbl=16.r7 h=7f29ce40f5f3tbl=18.r7 h=62d4d1322928tbl=20.r7 h=d96cb5c5effeapplies_to c11applies_to c7applies_to c8applies_to c7applies_to c8applies_to c7applies_to c6applies_to c6applies_to c9applies_to c9applies_to c6applies_to c7