UV fluorescence imaging is a non-destructive way to analyse failures in PV modules. A camera records the visible light that the encapsulant gives off when UV light shines on it. It has to be done in the dark, usually at night. Modules do not need to be disconnected or powered, and imaging one module usually takes less than 60 seconds. The method only works after sunlight has built up fluorescent products in the encapsulant. The suggested UV dose is about 80 kWh/m², which is roughly 1.5 years outdoors in Germany. Cell cracks show up as dark bars caused by photobleaching. A crack is easier to identify this way than in an EL image, but cracks at the cell edge or close to the interconnector are hard or impossible to see. It can also show isolated cell parts and disconnected cell interconnects. It can find cell cracks caused by glass breakage, and the signal also depends on the defect type, such as hotspots or broken glass. Used together with EL, it helps date damage, because new cracks appear only in EL until the fluorescence has had time to bleach. Drone-based night inspections need at least two trained people and calm conditions. The drone's battery drains quickly with the extra load. Modules with UVA-transparent EVA reduce how well the method works, and reading the results takes expertise that many O&M providers lack.

<!-- review notes

Claims

produces

c1 verified · fact Dark line in UVF image

A cell crack shows as a dark bar on the cell because the fluorescent encapsulant is photobleached along the crack, where oxygen diffusing through the backsheet reaches it. Number, position and orientation of cracks can be read from the image. Cracks at the cell edge cannot be seen because the cell border is bleached too.

verified by: joshuahamsaverified on: 2026-10-19

c2 verified · fact Uneven cell fluorescence

With a disconnected cell interconnect, current flows through only one ribbon. That side of the cell heats more and forms more lumophores, so it fluoresces more strongly. When part of a cell is isolated, the reverse-biased non-isolated part shows increased fluorescence.

verified by: joshuahamsaverified on: 2026-10-19