System Degradation vs Module Degradation
- ID
fm:system-vs-module-degradation
- IRI
https://solarlattice.org/kb/fm/system-vs-module-degradation
- Status
- active
- Category
- Modules
Module degradation is the power an individual module loses over time. System degradation is the energy the whole PV plant loses over time, and the two are not always equal. Modules in the field age at different rates. The weaker ones limit the current of the strings or substrings around them, so the extra mismatch makes the system lose more than the average module does. In practice the plant can show a larger drop in energy even while the average module is still within its warranty. To confirm it, compare long-term normalized plant output and string or inverter trends with IV curve data and module test results. This separates average module degradation from degradation caused by mismatch. Model degradation at the system level and include the spread between modules, not only the module warranty rate.
Claims
caused_by
c1 verified · fact
Module degradation
Individual modules lose power over time; system loss follows from this but is not always the same number.
verified by: joshuahamsaverified on: 2026-10-16review note: support check: partial - Passage says system and module degradation differ and mismatch arises from uneven aging, but doesn't state system degradation is caused by module degradation in general.
c2 verified · fact
Uneven module aging
Modules aging at different rates creates electrical mismatch, because weaker modules limit current in the strings or substrings around them.
verified by: joshuahamsaverified on: 2026-10-16
presents_as
c3 verified · fact
Gradual performance decline
The system energy decline can be larger than the average module loss, even while the average module is still within warranty.
verified by: joshuahamsaverified on: 2026-10-16
detected_by
c4 verified · fact
Normalized output trend analysis
Long-term normalized plant output helps separate average module degradation from degradation driven by mismatch.
verified by: joshuahamsaverified on: 2026-10-16
c5 verified · fact
String and inverter trending
verified by: joshuahamsaverified on: 2026-10-16
c6 drafted · lead
IV curve tracing
c7 drafted · lead
Flash testing
The source refers generally to module test results used to establish average module degradation.
review note: support check: partial - Passages mention generic 'module test results', not flash testing specifically, though the note acknowledges this generality.
mitigated_by
c8 drafted · lead
System-level degradation modeling
The performance model should include system-level degradation, not just module-level degradation.
c9 drafted · lead
Production forecast update
Use field measurements, module technology, warranty terms and IV or string data to update long-term energy assumptions.
degradation_rate
c10 verified · fact
nominal 0.1 PERCENT-PER-YR
Conditions: Modeling allowance that some independent engineers add on top of the module degradation rate to account for mismatch from uneven module aging; not a universal rule.
Some independent engineers add about 0.1% per year to the module degradation rate when evaluating system degradation.
verified by: joshuahamsaverified on: 2026-10-16