Mismatch loss is power lost because the modules in a string do not all have the same current-voltage characteristics, so their small differences in performance cost power. Because of this, the maximum output of the whole array is always lower than the sum of each module's maximum output. A slightly weaker module limits the string current and pulls the stronger modules away from their best operating point. Very weak modules or substrings get bypassed, and all of their power is lost. Mismatch is one of the capture losses. Yield models usually apply a module mismatch factor of about 0.98. Modules can become mismatched when they degrade at different rates, so system degradation can be higher than the degradation of the modules themselves. Floating PV and bifacial modules tend to have more mismatch, partly because modules moving with the waves change tilt and azimuth within a string. Power optimisers and other module-level power electronics reduce mismatch by tracking the maximum power point of each module. In the field, mismatch can be found with string-current comparisons on combiner monitoring, or with module-level mismatch reports. In those reports, mismatch beyond plus or minus 6 percent, or a sudden increase, calls for investigation.

<!-- review notes

Claims

typical_power_loss

c1 verified · fact ≥ 2 PERCENT

Conditions: Loss in system power from module-to-module performance inconsistencies, as stated in an IEA PVPS overview of typical losses

verified by: review-workflowverified on: 2026-10-24

c2 drafted · lead 0.97–0.99, nominal 0.98 UNITLESS

Conditions: Mismatch loss factor (multiplier) observed in the field: typical 0.98, low 0.97, high 0.99

Value is a derate factor, not a percentage loss.

degradation_rate

c3 drafted · lead nominal 0.1 PERCENT-PER-YR

Conditions: Approximate allowance some independent engineers add to the module degradation rate to cover mismatch from modules degrading at different rates; a modeling allowance, not a universal rule

part_of

c4 drafted · lead Array capture loss

Electrical mismatching is listed among the causes of capture losses.

explains

c5 drafted · lead System Degradation vs Module Degradation

Uneven module degradation creates extra mismatch, so system degradation can exceed module nameplate degradation.

related_to

c6 drafted · lead Module-level power electronics

Module-level MPPT with optimisers reduces mismatch losses.

c7 drafted · lead Bypass diode

Low-power modules or substrings can be bypassed, losing all their power.

c8 drafted · lead Floating PV

Relative module movement on water changes tilt and azimuth within a string and increases mismatch.

c9 drafted · lead Bypass Diode Failure

review note: support check: partial - Bypass diode failure entry is tagged 'module mismatch' and mentions upstream mismatch drivers, but the relation to mismatch loss is only loosely implied.