Grid curtailment loss happens when the plant could produce more power than it is allowed to export, so available solar energy goes unused. The limit can come from grid operator dispatch, an interconnection constraint, a plant controller command, a response to negative prices, or a site export cap. In the data it looks like a flat or controlled output level below what irradiance would support, while inverter and tracker availability look normal, so it is easily mistaken for underperformance. To confirm it, reconstruct available power from irradiance, temperature, inverter status, clipping state and modeled capability, and compare it with meter output, plant controller limits, dispatch signals and curtailment flags. Sort each constrained interval by cause, such as grid dispatch, export limit, economic curtailment, controller behavior, battery charging limit, outage or telemetry error, and at storage sites check whether curtailed energy was charged, clipped or abandoned. Track curtailment separately from equipment losses and use performance metrics built for curtailed plants, because a low performance ratio in curtailed hours does not mean the equipment is unhealthy. Where there is a battery, adjust the charging strategy so it can absorb curtailed energy when it has spare capacity and power headroom.
<!-- review notes
caused_byc1 verified · fact Grid operator dispatch
sec=h4 h=576525a653a1verified by: joshuahamsaverified on: 2026-10-16
c2 verified · fact Interconnection constraint
sec=h4 h=576525a653a1verified by: joshuahamsaverified on: 2026-10-16
c3 verified · fact Plant controller command
sec=h4 h=576525a653a1verified by: joshuahamsaverified on: 2026-10-16
c4 verified · fact Negative power pricing
Economic curtailment as a response to negative prices.
sec=h4 h=576525a653a1verified by: joshuahamsaverified on: 2026-10-16
c5 verified · fact Site export cap
sec=h4 h=576525a653a1verified by: joshuahamsaverified on: 2026-10-16
presents_asc6 drafted · lead Flat capped output
Output sits at a flat or controlled level under the power the irradiance would support.
sec=h4 h=576525a653a1c7 verified · fact Low output despite irradiance
Export is held below available plant power while inverter and tracker availability and equipment health look normal.
sec=h2 h=5fdb7733fc7csec=h4 h=576525a653a1verified by: joshuahamsaverified on: 2026-10-16
c8 drafted · lead Low performance ratio
Low PR in curtailed hours reflects grid instructions more than module, inverter or tracker health.
sec=h5 h=d55aa663f3f5detected_byc9 drafted · lead Setpoint and dispatch review
Review plant setpoints, inverter active power limits, grid operator dispatch signals and curtailment flags.
sec=h2 h=5fdb7733fc7csec=front h=874f05be8763sec=h4 h=576525a653a1c10 drafted · lead Available power reconstruction
Rebuild available power from irradiance, temperature, inverter status, clipping state and modeled capability, then compare with meter output and controller limits.
sec=h6 h=08e6be358742c11 verified · fact Constrained interval classification
Assign each constrained interval to grid dispatch, export limit, economic curtailment, controller behavior, BESS charging limit, outage or telemetry error.
sec=h6 h=08e6be358742verified by: joshuahamsaverified on: 2026-10-16
c12 verified · fact Battery charging review
At storage sites, check whether curtailed PV energy was charged, clipped or abandoned.
sec=h2 h=5fdb7733fc7csec=h6 h=08e6be358742verified by: joshuahamsaverified on: 2026-10-16
mitigated_byc13 drafted · lead Loss factor separation
Book curtailment apart from equipment losses.
sec=h2 h=5fdb7733fc7csec=front h=874f05be8763review note: reviewer 2026-10-19: target mit:separate-curtailment-tracking merged into mit:loss-factor-separation
c14 verified · fact Improved available-power estimation
sec=h2 h=5fdb7733fc7csec=front h=874f05be8763verified by: joshuahamsaverified on: 2026-10-16
c15 verified · fact Battery charging strategy tuning
Curtailed energy can be partly recovered by DC- or AC-coupled charging only if the battery has capacity, power headroom, control permission and an objective that values the charge.
sec=h2 h=5fdb7733fc7csec=h5 h=d55aa663f3f5verified by: joshuahamsaverified on: 2026-10-16
c16 verified · fact Curtailment-aware performance metrics
Avoids chasing false equipment faults at plants that are often constrained.
sec=h2 h=5fdb7733fc7csec=h7 h=779bcf6ddc67verified by: joshuahamsaverified on: 2026-10-16
explains c1distinguished_from c12distinguished_from c22distinguished_from c18distinguished_from c11