Scheduled periodic grid disconnection

ID
symptom:periodic-grid-disconnection
IRI
https://solarlattice.org/kb/symptom/periodic-grid-disconnection
Status
active
Also known as
Periodic GridOff

When the inverter reaches the grid connection time limit set by the grid standard, it disconnects from the grid by itself and then reconnects. The disconnection is there so the inverter can run its Riso insulation resistance test. The manuals say this alarm is not an error, because safety regulations require the automatic disconnection. Check first how often the event happens: if the inverter disconnects sooner than the expected interval, contact the manufacturer's customer assistance.

<!-- review notes

Claims

observed_as

c1 verified · fact Inverter fault code display

Warning code W048 with the message 'Periodic GridOff'. It is raised when the inverter disconnects and reconnects on its own to run the Riso (insulation resistance) test.