Some inverters raise an alarm when the phase of the grid at their AC terminals looks abnormal. Solis calls it PHASE FAULT. Check the installation first and confirm the grid wiring to the inverter is connected correctly, because a wiring error can cause this alarm. Then measure the grid to confirm the phases are 120 degrees apart. If the wiring and the grid phase angles are both correct, restart the inverter. If the fault comes back, the inverter itself is the likely cause and should be replaced. On microgrid controllers, a phase difference reading in degrees shows the angle between the grid-side and microgrid-side voltages during reconnection.