Also known as
module-to-ground voltage, high voltage stress

The voltage between a module's cells and its grounded frame grows as more modules are wired in series in a string. This voltage to ground drives leakage currents through the front glass and encapsulant, which causes Potential Induced Degradation (PID) and can sharply cut module and string power. In the shunting form of PID, sodium ions move from the glass into the cell and create shunts. In the polarization form, negative surface charges build up on the cell. Modules with p-type cells degrade in strings at negative polarity, and modules with n-type cells degrade in strings at positive polarity. Damage is worst in modules near one end of the string and in cells close to the frame. Exposure has grown because maximum system voltage has risen from 600 V to 1500 V. Transformerless inverters also often prevent grounding either end of the string. Heat, humidity, rain, condensation and soiling all speed up the damage, because they raise leakage current. To reduce the stress, use system grounding or offset strategies, choose PID-resistant modules, clean off conductive soiling, and consider qualified regeneration where appropriate.

<!-- review notes

Claims

typical_power_loss

c1 verified · fact nominal 41 PERCENT

Conditions: Average performance loss reported for a 10.7 MW plant in Spain affected by PID, cited by Libby et al.

This loss comes from PID, which is driven by voltage to ground. It is one plant's figure, not a general rate.

verified by: joshuahamsaverified on: 2026-10-20

c2 verified · fact ≥ 20 PERCENT

Conditions: Yield losses seen in past cases of PID within one year, caused by high voltage stress with respect to ground

Yield losses of 20 percent and more within 1 year were observed in the past.