Fan obstruction

ID
stressor:fan-obstruction
IRI
https://solarlattice.org/kb/stressor/fan-obstruction
Status
active
Also known as
Fan is blocked

Fan obstruction means foreign matter stops an inverter cooling fan from turning or blocks its air ducts. Fallen leaves, sand, debris dropping from a weathered wall, and animals are typical causes. A blocked fan cools the inverter poorly, which triggers over-temperature protection. This cuts power generation and can damage the inverter, especially in summer. Several inverter manuals list a blocked fan as a possible cause of the external or internal fan error alarm, which is a form of fan failure. Clogged heat sinks make the fans run a higher duty cycle and shorten fan life. Dust that blocks heat dissipation and soiled air filters can also cause overheating. The risk is highest where inverters are installed outdoors near overgrown plants or bushes, or in areas with heavy ash or fallen leaves. To reduce exposure, choose a clean site away from bushes and falling debris, add protection such as sun visors, and keep the clearances given in the product manual. In service, check fan status, clean the external fan regularly with a soft brush, and check the heat sink through the fan inlets. Clean it with pressurized air if needed. When a fan alarm appears, check the fan blades and ducts for foreign objects and remove them. If the fan still does not run, contact the manufacturer.