Product
Solis S6-EH3P(75-150)K10-NV-YD-H-US
- ID
prod:solis-s6-eh3p-75-150k-us
- IRI
https://solarlattice.org/kb/prod/solis-s6-eh3p-75-150k-us
- Status
- active
- Also known as
- S6-EH3P100K10-NV-YD-H-US, S6-EH3P125K10-NV-YD-H-US, S6-EH3P150K10-NV-YD-H-US, S6-EH3P60K10-LV-YD-H-US, S6-EH3P75K10-LV-YD-H-US
- Category
- Inverters
- Make
- solis
- Product level
- family
The Solis S6-EH3P(75-150)K10 US family is a series of three-phase hybrid inverters. The manual covers five models, from the 60K and 75K LV versions up to the 100K, 125K and 150K NV versions. The datasheet lists maximum apparent output power of 100 kVA, 125 kVA and 150 kVA for the 100K, 125K and 150K models. Rated output current is 120.3 A, 150.4 A and 180.4 A for those same models. The 75K model has a CEC efficiency of 95.2 percent and a maximum efficiency of 96.0 percent. The 100K and 125K models reach 97.2 percent CEC and 97.6 percent maximum efficiency. The rated frequency is 60 Hz. The 100K and 125K models have integrated AFCI 2.0 DC arc-fault protection. An AFCI-Check alarm means the arc-fault self-test failed. Restart the system first and check whether the fault comes back. A BatName-FAIL alarm means the battery brand chosen in the settings does not match the battery that is installed. Check the Battery Model setting against the battery module nameplate.
<!-- review notes
- sentence 1: support check: partial - Five models listed with LV/NV, but 'three-phase hybrid inverters' is not explicitly stated in the passage (only implied by model name).
- sentence 2: support check: partial - Apparent power for 100K/125K/150K is given as 100, 125, 150 kVA (row ordering) and currents match, but 'datasheet' mapping is by row layout; largely supported.
- sentence 5: support check: partial - AFCI and self-test failure with restart are supported, but 'check whether the fault comes back' is a paraphrase of 'confirm the fault continues'; acceptable, though the 100K/125K AFCI is supported.
- sentence 1: review: partial - The five models (60K and 75K LV; 100K, 125K and 150K NV) are supported, but 'three-phase hybrid inverters' is not stated in the passage.
- sentence 4: review: partial - The table gives 60 Hz as the rated input frequency only for the 75K, 100K and 125K models, so the general claim for the whole family is not fully covered.
-->
Claims
manufactured_by
c1 drafted · lead
Solis
review note: support check: partial - Models list is shown but nothing in the passages states the manufacturer beyond the bare 'solis' token; the 75K model is LV, not NV.
implements
c2 drafted · lead
DC arc-fault protection
Datasheet lists integrated AFCI 2.0 as Yes for the 100K and 125K models.
frequency
c3 drafted · lead
nominal 60 HZ
Conditions: Rated input frequency, 75K model
c4 verified · fact
nominal 60 HZ
Conditions: Rated input frequency, 100K and 125K models
verified by: review-workflowverified on: 2026-10-24
efficiency
c5 drafted · lead
nominal 95.2 PERCENT
Conditions: CEC efficiency, 75K model
review note: possible conflict with c6 (same source; check the conditions); possible conflict with c7 (same source; check the conditions); possible conflict with c8 (same source; check the conditions)
c6 drafted · lead
nominal 96 PERCENT
Conditions: Maximum efficiency, 75K model
review note: possible conflict with c5 (same source; check the conditions); possible conflict with c7 (same source; check the conditions); possible conflict with c8 (same source; check the conditions)
c7 drafted · lead
nominal 97.2 PERCENT
Conditions: CEC efficiency, 100K and 125K models
review note: possible conflict with c5 (same source; check the conditions); possible conflict with c6 (same source; check the conditions); possible conflict with c8 (same source; check the conditions)
c8 verified · fact
nominal 97.6 PERCENT
Conditions: Maximum efficiency, 100K and 125K models
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c5 (same source; check the conditions); possible conflict with c6 (same source; check the conditions); possible conflict with c7 (same source; check the conditions)
rated_output_current
c9 verified · fact
nominal 120.3 A
Conditions: Rated output current, 100K model
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c10 (same source; check the conditions); possible conflict with c11 (same source; check the conditions)
c10 verified · fact
nominal 150.4 A
Conditions: Rated output current, 125K model
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c9 (same source; check the conditions); possible conflict with c11 (same source; check the conditions)
c11 drafted · lead
nominal 180.4 A
Conditions: Rated output current, 150K model
review note: possible conflict with c9 (same source; check the conditions); possible conflict with c10 (same source; check the conditions)
Referenced by
Data