Solar Lattice

Product

Solis S6-EH1P(3.8-11.4)K-H-US

ID
prod:solis-s6-eh1p-h-us
IRI
https://solarlattice.org/kb/prod/solis-s6-eh1p-h-us
Status
active
Also known as
S6-EH1P3.8K-H-US, S6-EH1P5K-H-US, S6-EH1P7.6K-H-US, S6-EH1P9.9K-H-US, S6-EH1P10K-H-US, S6-EH1P11.4K-H-US
Category
Inverters
Make
solis
Product level
family

The Solis S6-EH1P(3.8-11.4)K-H-US is a family of single-phase hybrid inverters from Solis. They are transformerless, bi-directional, utility-interactive units with grid support, and they are permanently connected. The certification listing names the 3.8, 5, 7.6, 9.9, 10 and 11.4 kW models, among others. Every model has an integrated AFCI for DC arc-fault protection and has ground fault detection. DC reverse-polarity protection covers the PV inputs only. The technical data refers to a separate compatibility list for the supported rapid shutdown receivers and for the number of batteries per inverter. The family holds a CSA certification under a product class covering power systems equipment certified to U.S. standards. The alarm messages include 12Power-FAULT for a 12 V supply fault, AFCI Check FAULT for an AFCI self-check fault, and DSP-B-FAULT for lost communication between the main and slave DSPs. For each one, the advice is to restart the inverter or contact the installer.

<!-- review notes

Claims

manufactured_by

c1 drafted · lead Solis

review note: support check: partial - The passage is only the word 'solis', which names the manufacturer loosely but doesn't state that this product is made by Solis.

instance_of

c2 drafted · lead Inverter

Listed as bi-directional transformerless grid support utility interactive power conversion equipment, permanently connected.

implements

c3 drafted · lead DC arc-fault protection

Integrated AFCI listed as Yes for the 3.8, 5, 7.6, 9.9, 10 and 11.4 kW models.

review note: support check: partial - AFCI is listed Yes for 3.8, 5, 7.6, 9.9, 10 and 11.4 kW models, but the passages don't cover the other models, such as 6 and 8 kW.

c4 drafted · lead DC ground-fault protection

Ground fault detection listed as Yes in the technical data tables.

c5 drafted · lead Reverse polarity protection

DC reverse-polarity protection applies to the PV inputs only.