- Solis_Manual_S6-EH1P(3.8-11.4)K-H-US_v.5.6_20260413
sec=fronth=65d0ffd891c8
review note: support check: partial - The passage is only the word 'solis', which names the manufacturer loosely but doesn't state that this product is made by Solis.
The Solis S6-EH1P(3.8-11.4)K-H-US is a family of single-phase hybrid inverters from Solis. They are transformerless, bi-directional, utility-interactive units with grid support, and they are permanently connected. The certification listing names the 3.8, 5, 7.6, 9.9, 10 and 11.4 kW models, among others. Every model has an integrated AFCI for DC arc-fault protection and has ground fault detection. DC reverse-polarity protection covers the PV inputs only. The technical data refers to a separate compatibility list for the supported rapid shutdown receivers and for the number of batteries per inverter. The family holds a CSA certification under a product class covering power systems equipment certified to U.S. standards. The alarm messages include 12Power-FAULT for a 12 V supply fault, AFCI Check FAULT for an AFCI self-check fault, and DSP-B-FAULT for lost communication between the main and slave DSPs. For each one, the advice is to restart the inverter or contact the installer.
<!-- review notes
manufactured_bysec=front h=65d0ffd891c8review note: support check: partial - The passage is only the word 'solis', which names the manufacturer loosely but doesn't state that this product is made by Solis.
instance_ofListed as bi-directional transformerless grid support utility interactive power conversion equipment, permanently connected.
sec=h295 h=7f223e1bec10sec=h302 h=bfdb64161fcbimplementsc3 drafted · lead DC arc-fault protection
Integrated AFCI listed as Yes for the 3.8, 5, 7.6, 9.9, 10 and 11.4 kW models.
tbl=24.r24 h=9fe41bf4e353tbl=18.r24 h=ea291ef4e968tbl=21.r24 h=01331fa477catbl=27.r24 h=c8b96dc649c0review note: support check: partial - AFCI is listed Yes for 3.8, 5, 7.6, 9.9, 10 and 11.4 kW models, but the passages don't cover the other models, such as 6 and 8 kW.
c4 drafted · lead DC ground-fault protection
Ground fault detection listed as Yes in the technical data tables.
tbl=18.r22 h=a51867873d79tbl=24.r22 h=313fd2091907tbl=21.r22 h=46a38bb50c53tbl=27.r22 h=40b39ae6dff4c5 drafted · lead Reverse polarity protection
DC reverse-polarity protection applies to the PV inputs only.
tbl=18.r25 h=85b70a18579atbl=24.r25 h=a098d9570204tbl=27.r25 h=373b5578d090tbl=21.r25 h=802746864b1dapplies_to c8applies_to c9applies_to c8applies_to c9applies_to c11applies_to c8applies_to c4applies_to c7applies_to c9applies_to c10applies_to c7applies_to c6applies_to c8applies_to c5applies_to c10applies_to c8applies_to c5applies_to c10applies_to c6applies_to c4applies_to c9applies_to c6applies_to c8applies_to c5applies_to c11applies_to c6applies_to c5applies_to c5applies_to c11applies_to c8applies_to c6applies_to c5applies_to c5compatible_with c7incompatible_with c8