- Solis Manual S5 (75-100)K US V2,3(20230623)
sec=h1h=3e00c077410c
Solis S5-GC(75-125)K-US
The Solis S5 Series is a three-phase grid-tied string inverter family for the US market, covering the S5-GC75K-US, S5-GC80K-US, S5-GC90K-US and S5-GC100K-US models. The S5-GC75K-US connects to a 480 V three-phase grid with PE and has a rated output current of 90.2 A, while the S5-GC100K-US is rated at 108.3 A. On the S5-GC75K-US, maximum input current is listed as 8x32 A. Maximum efficiency is 98.7% for the 75K model and 98.8% for the 100K model, and the 75K model has a CEC efficiency of 98.3%. Current distortion is below 3% at rated output power. RS485 is the standard communication link, and Wi-Fi or cellular can be added as options; the unit has an LCD display.
<!-- review notes
- sentence 1: support check: partial - Models listed, but three-phase, string inverter and US market are only implied by names/3/PE, not explicitly stated.
- sentence 1: review: partial - The passage names the S5 Series Grid Inverter and the four models, but 'three-phase', 'string' and 'US market' are not stated (the US market is only hinted at by the -US suffix). -->
Claims
manufactured_by
uses_protocol
Standard communication connection on all models
- Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=16.r35h=a24bedbf8940 - Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=19.r35h=0c1dbcc42ab3 - Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=17.r36h=1e607db0967f - Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=18.r36h=1e607db0967f
Optional communication connection
- Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=16.r35h=a24bedbf8940 - Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=19.r35h=0c1dbcc42ab3 - Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=17.r36h=1e607db0967f - Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=18.r36h=1e607db0967f
c4 drafted · lead Cellular data
Optional communication connection
- Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=16.r35h=a24bedbf8940 - Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=19.r35h=0c1dbcc42ab3 - Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=17.r36h=1e607db0967f - Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=18.r36h=1e607db0967f
efficiency
c5 drafted · lead nominal 98.7 PERCENT
Conditions: Maximum efficiency, S5-GC75K-US
- Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=16.r17h=9699a08efe38
review note: possible conflict with c6 (same source; check the conditions); possible conflict with c7 (same source; check the conditions)
c6 drafted · lead nominal 98.8 PERCENT
Conditions: Maximum efficiency, S5-GC100K-US
- Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=19.r17h=446ae11f775b
review note: possible conflict with c5 (same source; check the conditions); possible conflict with c7 (same source; check the conditions)
c7 drafted · lead nominal 98.3 PERCENT
Conditions: CEC efficiency, S5-GC75K-US
- Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=16.r18h=ba8e370b74b4
review note: possible conflict with c5 (same source; check the conditions); possible conflict with c6 (same source; check the conditions)
rated_output_current
c8 verified · fact nominal 90.2 A
Conditions: Rated output current, S5-GC75K-US
- Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=16.r13h=6c3250a08603
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c9 (same source; check the conditions)
c9 verified · fact nominal 108.3 A
Conditions: Rated output current, S5-GC100K-US
- Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=19.r13h=f212e99a964f
verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c8 (same source; check the conditions)
max_input_current
c10 verified · fact nominal 32 A
Conditions: Per input, printed as 8x32, S5-GC75K-US
- Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=16.r6h=f670065548d8
verified by: review-workflowverified on: 2026-10-24
nominal_voltage
c11 drafted · lead nominal 480 V
Conditions: Rated grid voltage, three-phase plus PE (3/PE~480), S5-GC75K-US
- Solis Manual S5 (75-100)K US V2,3(20230623)
tbl=16.r12h=ec6bd7465e8b
Referenced by
- Solis S5-GC ARC-FAULT
applies_toc12 - Solis S5-GC GRID-INTF
applies_toc8 - Solis S5-GC INI-FAULT
applies_toc9 - Solis S5-GC NO-GRID
applies_toc10 - Solis S5-GC OV-BUS
applies_toc8 - Solis S5-GC OV-DC
applies_toc7 - Solis S5-GC OV-G-F
applies_toc7 - Solis S5-GC OV-G-V
applies_toc7 - Solis S5-GC OV-TEM
applies_toc12 - Solis S5-GC PV ISO-PRO 01/02
applies_toc13 - Solis S5-GC Reve-DC
applies_toc8 - Solis S5-GC UN-BUS
applies_toc9 - Solis S5-GC UN-G-V
applies_toc8