The Sunny Mini Central (SMC) is a family of older SMA string inverters. It includes the SMC 9000TL-10 to 11000TL-10, the TLRP-10 versions, the 7000HV, the 6000TL to 8000TL and the 4600A to 6000A models. The SMC9000TL, SMC10000TL and SMC11000TL accept up to 700 V DC, with maximum PV input currents of 28 A, 31 A and 34 A. Each connects to a single phase with neutral and protective earth. Every unit has the SMA Power Balancer built in. It links three units on different phases and offers the Fault Guard, Phase Guard, Power Guard and Off modes. It is switched off at the factory, and you need the SMA Grid Guard code to change it. The Sunny WebBox lists all Sunny Mini Central devices as supported, both under its SMA-NET protocol setting and under its SMA-COM interface setting. Known issue: replacement SMC9000TL to 11000TL units ship without string fuses and stay dark until you move the fuses over from the failed unit. If the unit is still dark after that, check the ribbon cable with the strings disconnected. A flashing red LED on the SMC-TL-10 models goes with the display messages Check DC Fuse or Check Varistor. SMA now suggests replacing a failed SMC9-11000TL(-RP)-10 with a Sunny Tripower STPxx-50, and one such unit can often replace three SMCs. For RS485 systems this needs the MD.485-41 module and a minimum firmware version.

<!-- review notes

Claims

instance_of

c1 verified · fact Inverter

verified by: review-workflowverified on: 2026-10-24review note: support check: partial - Passage says these are Sunny Mini Central inverters (string inverters) but does not explicitly state the class beyond 'inverters'; essentially supported.

manufactured_by

c2 drafted · lead SMA

compatible_with

c3 drafted · lead Sunny WebBox

Conditions: The Sunny WebBox documentation lists all Sunny Mini Central devices for its SMA-NET protocol setting and its SMA-COM interface setting

uses_protocol

c4 verified · fact SMA-NET proposed

Conditions: Protocol selected on the Sunny WebBox for Sunny Mini Central devices

verified by: review-workflowverified on: 2026-10-24

implements

c5 drafted · lead Phase balancing

Conditions: SMA Power Balancer, fitted as standard, links 3 Sunny Mini Central units on phases L1, L2 and L3; deactivated at the factory; modes Fault Guard, Phase Guard, Power Guard, Off

requires

c6 drafted · lead Grid Guard code holder

Conditions: Needed to change the PowerBalancer parameter, which can only be set through a communication device

has_hazard

c7 drafted · lead Electric shock

Conditions: DC voltage stays in the device unless the strings are disconnected; pulling the ESS handle does not de-energize it

review note: support check: partial - Passage says DC voltage is present unless strings are disconnected and pulling the ESS handle is insufficient, but does not name electric shock as a hazard.

max_count

c8 drafted · lead nominal 3 NUM

Conditions: Sunny Mini Central inverters per SMA Power Balancer group in a three-phase feed-in system, each on a different line conductor

max_input_voltage

c9 drafted · lead nominal 700 V

Conditions: UPV max for SMC9000TL, SMC10000TL and SMC11000TL, from the replacement table

max_input_current

c10 drafted · lead nominal 28 A

Conditions: IPV max for SMC9000TL, from the replacement table

review note: possible conflict with c11 (same source; check the conditions); possible conflict with c12 (same source; check the conditions)

c11 drafted · lead nominal 31 A

Conditions: IPV max for SMC10000TL, from the replacement table

review note: possible conflict with c10 (same source; check the conditions); possible conflict with c12 (same source; check the conditions)

c12 verified · fact nominal 34 A

Conditions: IPV max for SMC11000TL, from the replacement table

verified by: review-workflowverified on: 2026-10-24review note: possible conflict with c10 (same source; check the conditions); possible conflict with c11 (same source; check the conditions)

rated_output_current

c13 drafted · lead nominal 31 A

Conditions: Maximum output current of the Sunny Mini Central 7000HV

review note: support check: partial - Maximum output current of SMC 7000HV is 31 A, but it is labeled maximum, not rated output current.; review: partial - The passage gives 31 A as the maximum output current of the SMC 7000HV, but the claim calls it rated output current, which the passage does not state.