c1 drafted · lead Canadian Solar
- CSI Manual 50-66KTL-GS-FL v1.2 2017-09-07
sec=h4h=457d53016613 - CSI Manual 50-66KTL-GS-FL v1.2 2017-09-07
sec=1.1h=4ca42001f1a4
The CSI-50/60/66KTL-GS-FL family is a line of Canadian Solar three-phase grid-tied PV inverters. They convert DC from the array into AC that can supply local loads and feed the grid. The manual covers four models: CSI-50KTL-GS-FL, CSI-50KTL-GS, CSI-60KTL-GS and CSI-66KTL-GS. They are rated at 50, 60 and 66 kW on a 480 V AC grid. The 50 kW models have a rated grid output current of 60.2 A, and the manual's maximum efficiency figure is above 98.8 percent. The units are transformerless, NEMA 4X enclosures. Surge protection is DC class II, with AC class III as an option. Over- and under-voltage and frequency trip times can be set in the grid protection settings. Listed compliance includes CSA C22.2 No. 107.1, UL 1741, IEEE 1547, UL 1998 and FCC Part 15 Class B.
manufactured_byc1 drafted · lead Canadian Solar
sec=h4 h=457d53016613sec=1.1 h=4ca42001f1a4instance_ofThree-phase grid-tied PV inverter that converts DC from the PV array to AC for local loads and the grid.
sec=1.1 h=4ca42001f1a4rated_powerc3 drafted · lead nominal 50 KiloW
Conditions: CSI-50KTL-GS-FL and CSI-50KTL-GS
tbl=10.r5 h=39692e0bbd5ctbl=4 h=9494d62ae21areview note: possible conflict with c4 (same source; check the conditions); possible conflict with c5 (same source; check the conditions)
c4 drafted · lead nominal 60 KiloW
Conditions: CSI-60KTL-GS
tbl=12.r5 h=2d5bbbfe8255tbl=4 h=9494d62ae21areview note: possible conflict with c3 (same source; check the conditions); possible conflict with c5 (same source; check the conditions)
c5 drafted · lead nominal 66 KiloW
Conditions: CSI-66KTL-GS
tbl=12.r5 h=2d5bbbfe8255tbl=4 h=9494d62ae21areview note: possible conflict with c3 (same source; check the conditions); possible conflict with c4 (same source; check the conditions)
nominal_voltagec6 verified · fact nominal 480 V
Conditions: Rated AC grid voltage, all models
tbl=10.r7 h=0cbe6c7ce074tbl=12.r7 h=a78e7f9831bctbl=4 h=9494d62ae21averified by: review-workflowverified on: 2026-10-24
rated_output_currentc7 drafted · lead nominal 60.2 A
Conditions: Rated grid output current, CSI-50KTL-GS-FL
tbl=10.r10 h=e31fa652cfebefficiencyc8 drafted · lead ≥ 98.8 PERCENT
Conditions: Maximum efficiency, CSI-50KTL-GS-FL
tbl=10.r15 h=d2f08153561dc9 drafted · lead ≥ 98.8 PERCENT
Conditions: Maximum efficiency, CSI-60KTL-GS and CSI-66KTL-GS
tbl=12.r15 h=ec814b828491frequencyc10 verified · fact 59.5–60.5 HZ
Conditions: Operating range of utility frequency, CSI-50KTL-GS-FL
tbl=10.r25 h=b6c26b60f172verified by: review-workflowverified on: 2026-10-24
certified_toc11 drafted · lead UL 1741 proposed
tbl=10.r26 h=e45b121aaf9ctbl=12.r26 h=8f0d98bb63fac12 drafted · lead IEEE 1547 proposed
tbl=10.r26 h=e45b121aaf9creview note: support check: partial - IEEE1547 is listed as compliance for the 50 kW model; 60/66 passage shows garbled 'IEEE1S47', and 'certified' is stronger than 'compliance' listing.; review: partial - IEEE1547 compliance is listed only for the 50KTL-GS-FL model, so the claim's coverage of the 60/66 models is not shown in the quoted passage.
c13 drafted · lead CSA C22.2 No. 107.1 proposed
tbl=10.r26 h=e45b121aaf9ctbl=12.r26 h=8f0d98bb63fac14 drafted · lead UL 1998 proposed
tbl=10.r26 h=e45b121aaf9ctbl=12.r26 h=8f0d98bb63fac15 drafted · lead FCC Part 15 proposed
Class B
tbl=10.r26 h=e45b121aaf9cuses_protocolListed as an interface option
tbl=12.r23 h=8fdc3a52def5review note: support check: partial - WIFI listed as interface only for the 60/66 models in the passage, not the -FL model.; review: partial - WIFI is listed as an interface only for the 60KTL-GS and 66KTL-GS models, not for the 50KTL-GS-FL model, so the claim's coverage of the whole family is not fully supported.
c17 drafted · lead Cellular data
GPRS listed as optional interface
tbl=12.r23 h=8fdc3a52def5review note: support check: partial - GPRS optional interface is listed only for the 60/66 models, not the -FL model; GPRS as cellular is implied.
implementsc18 drafted · lead Surge protection
Protection listed as DC class II, AC class III optional
tbl=10.r16 h=013a0e96a248tbl=12.r16 h=5e85fdf490d0applies_to c11applies_to c7applies_to c2applies_to c7applies_to c7applies_to c8applies_to c7applies_to c6applies_to c6applies_to c2applies_to c6applies_to c7