The CSI-25/30/36/40KTL-GS-FL is a family of three-phase, grid-tied, transformerless string inverters from Canadian Solar that turn PV array DC into AC for on-site loads and the grid. The 36 and 40 kW models connect to a 480 Vac grid and carry rated output currents of 43.3 A and 48.1 A; the 25 and 30 kW models are rated at 30.1 A and 36.1 A. Maximum efficiency is above 98.6 percent, and grid current THD stays below 3 percent. The 25 and 30 kW models are specified to run from -25 to 60 °C and over a utility frequency range of 59.5 to 60.5 Hz. The enclosure is rated NEMA 4X, and the datasheet gives a design lifetime of more than 20 years.

<!-- review notes

Claims

manufactured_by

c1 drafted · lead Canadian Solar

instance_of

c2 drafted · lead Inverter

rated_power

c3 drafted · lead nominal 36 KiloW

Conditions: CSI-36KTL-GS-FL rated output power

review note: possible conflict with c4 (same source; check the conditions)

c4 drafted · lead nominal 40 KiloW

Conditions: CSI-40KTL-GS-FL rated output power

review note: possible conflict with c3 (same source; check the conditions)

rated_output_current

c5 drafted · lead nominal 30.1 A

Conditions: CSI-25KTL-GS-FL rated grid output current (AC)

review note: possible conflict with c6 (same source; check the conditions); possible conflict with c7 (same source; check the conditions); possible conflict with c8 (same source; check the conditions)

c6 drafted · lead nominal 36.1 A

Conditions: CSI-30KTL-GS-FL rated grid output current (AC)

review note: possible conflict with c5 (same source; check the conditions); possible conflict with c7 (same source; check the conditions); possible conflict with c8 (same source; check the conditions)

c7 drafted · lead nominal 43.3 A

Conditions: CSI-36KTL-GS-FL rated grid output current (AC)

review note: possible conflict with c5 (same source; check the conditions); possible conflict with c6 (same source; check the conditions); possible conflict with c8 (same source; check the conditions)

c8 drafted · lead nominal 48.1 A

Conditions: CSI-40KTL-GS-FL rated grid output current (AC)

review note: possible conflict with c5 (same source; check the conditions); possible conflict with c6 (same source; check the conditions); possible conflict with c7 (same source; check the conditions)

nominal_voltage

c9 drafted · lead nominal 480 V

Conditions: Rated AC grid voltage, three phase, CSI-36KTL-GS-FL and CSI-40KTL-GS-FL

efficiency

c10 drafted · lead ≥ 98.6 PERCENT

Conditions: Maximum efficiency, CSI-25KTL-GS-FL and CSI-30KTL-GS-FL

c11 drafted · lead ≥ 98.6 PERCENT

Conditions: Maximum efficiency, CSI-36KTL-GS-FL and CSI-40KTL-GS-FL

operating_temperature

c12 drafted · lead -25–60 DEG_C

Conditions: Running temperature, CSI-25KTL-GS-FL and CSI-30KTL-GS-FL

frequency

c13 drafted · lead 59.5–60.5 HZ

Conditions: Utility frequency operating range, CSI-25KTL-GS-FL and CSI-30KTL-GS-FL

certified_to

c14 drafted · lead UL 1741 proposed

c15 drafted · lead IEEE 1547 proposed

c16 drafted · lead CSA C22.2 No. 107.1 proposed

c17 verified · fact UL 1998 proposed

verified by: review-workflowverified on: 2026-10-24

c18 drafted · lead FCC Part 15 proposed

Class B

uses_protocol

c19 drafted · lead Wi-Fi

Listed among interfaces; option status per datasheet

review note: review: partial - The passage lists WIFI as an interface only for the 36KTL and 40KTL models, so the claim's coverage of the 25/30 models is not shown.

c20 drafted · lead Cellular data

GPRS, optional