Product
AlsoEnergy weather station (digitizer and sensor kit)
- ID
prod:alsoenergy-weather-station
- IRI
https://solarlattice.org/kb/prod/alsoenergy-weather-station
- Status
- active
- Also known as
- AlsoEnergy Weather Station, WS-BC-01, WS-AMB-01, WS-WD-01, WS-BR-PY2, WS-IT-MP, WS-IT-RC, WS-KZ-SP2, Integrated Weather Station Digitizer, Signal Conditioner / Digitizer, weather station digitizer
- Category
- Sensors
- Make
- alsoenergy
- Product level
- family
The digitizer converts the analog sensor signals to digital values and sends them to the AlsoEnergy Data Logger over a Modbus RTU link on an RS-485 interface. It has six sensor inputs: two low-level, low-noise analog inputs, two inputs for 0-10 VDC or 4-20 mA, and two pulse inputs. The standard kit measures module temperature, ambient temperature, solar irradiance, and wind speed and direction. Relative humidity, barometric pressure and rain gauge sensors are optional add-ons. Terminals P1 and P2 supply +24 VDC, P8 and P10 take millivolt pyranometer signals, P10 also takes wind direction, and P12 supplies +2.5 VDC for the Davis wind sensor only. Mount the anemometer pointing north. The clear pyranometer shield wire does not go to the digitizer; it lands on the shield terminal of the RS-485 field terminal block. The Modbus ground is isolated from the analog and pulse grounds, and configuration and pulse data are kept in nonvolatile memory.
<!-- review notes
- sentence 1: support check: partial - Conversion and Modbus RTU to the logger are stated, and the MODBUS/485 interface is mentioned, but nothing explicitly ties the Modbus RTU link to RS-485 to the logger.
-->
Models and variants
Claims
manufactured_by
c1 drafted · lead
AlsoEnergy proposed
review note: support check: partial - Passages describe the AlsoEnergy Weather Station and digitizer but never explicitly state AlsoEnergy makes it, though the name strongly implies it.
uses_protocol
c2 drafted · lead
Modbus RTU
Digitizer sends converted sensor values to the AlsoEnergy Data Logger over Modbus RTU.
c3 drafted · lead
Modbus
c4 drafted · lead
RS-485
MODBUS/485 interface; Modbus ground is isolated from analog and pulse grounds.
c5 drafted · lead
4-20 mA current loop
Two analog inputs accept 0-10 VDC or 4-20 mA; terminals P4 and P6 carry 4-20 mA temperature signals.
max_count
c6 drafted · lead
nominal 6 NUM
Conditions: Sensor inputs per digitizer: 2 low-level analog (0-25 mV, 0-250 mV, 0-2.5 V), 2 analog (0-10 VDC or 4-20 mA), 2 pulse