c1 drafted · lead AlsoEnergy proposed
- AlsoEnergy CH-E0-1000 PowerLogger1000 Datasheet v2
sec=h1h=13617579a61c - AlsoEnergy Installation Manual PV - REV 13
sec=2.2.2h=f35bc167c8b3
The AlsoEnergy PowerLogger 1000 is the standard gateway data logger for AlsoEnergy's commercial PV monitoring solution, and it has a touch screen for on-site work without a laptop. It is usually mounted in a NEMA4 enclosure together with a power supply, cellular modem, network switch and revenue grade meter. It ships pre-loaded with AlsoEnergy software and configuration, and it polls inverters, meters and weather stations over Modbus RTU, Modbus TCP or DNP3. One logger supports up to 40 devices, with a recommended maximum of 20 per port. It uploads data to the cloud-based PowerTrack platform, typically every 3 to 5 minutes. During network outages it buffers data on a removable SD card and uploads it once the network is back. It supports automatic remote firmware updates and manual remote control to clear inverter faults, switch inverters off and on, and operate switchgear where permitted. It is listed to UL 60950-1 and CSA C22.2 and meets FCC Part 15 Subpart B Class A. It carries a standard 5-year warranty.
manufactured_byc1 drafted · lead AlsoEnergy proposed
sec=h1 h=13617579a61csec=2.2.2 h=f35bc167c8b3instance_ofc2 drafted · lead Monitoring data logger
sec=h1 h=13617579a61csec=2.2.2 h=f35bc167c8b3uses_protocolc3 verified · fact Modbus RTU
Used to connect to inverters, meters and weather stations.
sec=2.2.2 h=f35bc167c8b3sec=2.2.2 h=f35bc167c8b3sec=4.2.2 h=58aac43aca61verified by: review-workflowverified on: 2026-10-24
c4 drafted · lead Modbus TCP
Used to connect to inverters, meters and weather stations.
sec=2.2.2 h=f35bc167c8b3sec=2.2.2 h=f35bc167c8b3sec=4.2.2 h=58aac43aca61Other protocols available with vendor cooperation.
sec=2.2.2 h=f35bc167c8b3sec=2.2.2 h=f35bc167c8b3sec=4.2.2 h=58aac43aca61certified_toc6 drafted · lead UL 60950-1 proposed
tbl=6.r2 h=c5c35244b828review note: support check: partial - Passage says 'Listed to UL 60950-1', not certified; listing is close but not exactly certification.
c7 drafted · lead FCC Part 15B proposed
Class A.
tbl=6.r2 h=c5c35244b828review note: support check: partial - Passage says listed to FCC Part 15 Subpart B Class A; 'certified' wording is slightly stronger but core matches.
requiresc8 drafted · lead AlsoEnergy PowerTrack platform and API
Designed for use with the cloud-based PowerTrack software; sends real-time field data and diagnostics to it.
sec=h3 h=8ee2f59c00cesec=h2 h=cb3a85689752implementsc9 drafted · lead Remote firmware update
Automatic remote firmware updates.
sec=2.2.2 h=f35bc167c8b3sec=2.2.2 h=f35bc167c8b3c10 drafted · lead Data backfill after communication loss
Data stored on a removable SD card during network outages and uploaded once the network is restored.
sec=2.2.2 h=f35bc167c8b3sec=2.2.2 h=f35bc167c8b3sec=4.2.2 h=58aac43aca61sec=h2 h=cb3a85689752c11 verified · fact Remote inverter control proposed
Manual remote control to clear inverter faults, switch inverters off and on, and operate switchgear where permitted.
sec=h2 h=cb3a85689752verified by: review-workflowverified on: 2026-10-24
max_countConditions: Total connected devices supported per logger
sec=2.2.2 h=f35bc167c8b3sec=2.2.2 h=f35bc167c8b3sec=4.2.2 h=58aac43aca61verified by: review-workflowverified on: 2026-10-24
warranty_termc13 drafted · lead nominal 5 YR
Conditions: Standard warranty for AlsoEnergy integrated hardware solutions
sec=h1 h=13617579a61csec=h1 h=13617579a61c