Direct sunlight avoidance
Direct sunlight avoidance means mounting the inverter in a shaded place so the sun does not shine directly on it. It is part of installing the inverter correctly. Mounting an inverter in direct sun goes against the instruction manual and is one cause of incorrect inverter installation. Incorrect installation can lead to inverter overheating. Direct sun on the inverter can limit its power output and reduce energy yield. It can also wear out electrical parts, gaskets and the user interface early. Choose shaded spots or walls that do not face the sun. One manufacturer recommends mounting the inverter facing north to keep sun exposure low. If there is no shade, build a simple shade structure above the inverter. Some manufacturers require their shade cover accessory when the inverter is mounted tilted backward outdoors. Keep air moving around the inverter so it can shed heat. If a metal back sheet sits in direct sun, leave 30 cm between it and the inverter, because less clearance can make the inverter start derating early. Some inverters are rated to run in direct sun and rain, but shading is still recommended for best performance and a longer life. Inverters mounted on indoor walls with no sun exposure do not need special clearance.
Referenced by
- Inverter cooling
related_toc8 - ABB / FIMER PVS-166-175-TL E014
mitigated_byc5 - ABB / FIMER PVS-60-TL CODE:05
mitigated_byc5 - ABB / FIMER PVS-60-TL E014
mitigated_byc5 - ABB / FIMER PVS-60-TL E056
mitigated_byc4 - ABB / FIMER TRIO-20.0-27.6-TL CODE:05
mitigated_byc5 - ABB / FIMER TRIO-20.0-27.6-TL E014
mitigated_byc5 - ABB / FIMER TRIO-20.0-27.6-TL E056
mitigated_byc4 - ABB / FIMER UNO-DM-3.3-5.0-PLUS CODE:05
mitigated_byc5 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E014
mitigated_byc6 - ABB / FIMER UNO-DM-3.3-5.0-PLUS E056
mitigated_byc5 - ABB / FIMER UNO-DM-6.0-PLUS CODE:05
mitigated_byc5 - ABB / FIMER UNO-DM-6.0-PLUS E014
mitigated_byc6 - ABB / FIMER UNO-DM-6.0-PLUS E056
mitigated_byc5 - Canadian Solar 185-255K OV-TEM
mitigated_byc7 - Canadian Solar 25-40K-T480GL01 OV-TEM
mitigated_byc7 - Canadian Solar 50-66K-T480GL01 OV-TEM
mitigated_byc7 - Canadian Solar 75-100K-T480GL02 OV-TEM
mitigated_byc7 - Schneider Electric CL125 036
mitigated_byc5 - SMA SB-US-40 8003
mitigated_byc8 - SMA SB-US-41 8003
mitigated_byc8 - SMA SBSE-US-50 6501
mitigated_byc10 - SMA SBSE-US-50 6511
mitigated_byc6 - SMA SBSE-US-50 8003
mitigated_byc8 - SMA PEAK3-US 6501
mitigated_byc10 - SMA PEAK3-US 6511
mitigated_byc6 - SMA PEAK3-US 8003
mitigated_byc8 - SMA CORE1-US 8003
mitigated_byc9 - SMA STP-X-US 6501
mitigated_byc10 - SMA STP-X-US 6511
mitigated_byc6 - SMA SC-CP-XT 6501
mitigated_byc10 - Solis 1P-4G-US OV-TEM
mitigated_byc7 - Solis 3P-5G-US OV-TEM
mitigated_byc6 - Solis RHI-1P-HV OV-TEM
mitigated_byc6 - Solis S5-GC OV-TEM
mitigated_byc6 - Solis S6-EH1P OV-TEM
mitigated_byc6 - Solis S6-EH2P OV-TEM
mitigated_byc6 - Solis S6-EH3P30-60K OV-TEM
mitigated_byc7 - Solis S6-EH3P75-150K OV-TEM
mitigated_byc6 - Solis S6-GC OV-TEM
mitigated_byc7 - Solis S6-GU OV-TEM
mitigated_byc6 - Sungrow SG-CX-US 036
mitigated_byc6 - Sungrow SG-CX-US 037
mitigated_byc7 - Sungrow SG200HX 036
mitigated_byc5 - Sungrow SG200HX 037
mitigated_byc6 - Sungrow SG250HX 36
mitigated_byc4 - Sungrow SG250HX 37
mitigated_byc4 - Sungrow SG350HX 036
mitigated_byc5 - Sungrow SG350HX 037
mitigated_byc6 - Inverter Incorrect Installation
mitigated_byc12