Solar Lattice

Measurement

AC disconnect open position

ID
meas:ac-disconnect-open
IRI
https://solarlattice.org/kb/meas/ac-disconnect-open
Status
active
Also known as
AC disconnection unit, AC disconnect switch, AC service disconnect switch, AC disconnect device, main PV system AC disconnect

This signature is the physical position of the AC disconnect, read on the handle or knob, which shows whether the inverter is cut off from the AC side. On the ABB AC disconnection unit in SMA central inverters the handle has three positions: on means closed, the central position means the unit tripped and is open, and off means it is open. On SMA US string inverters, opening the main PV system AC disconnect starts the Rapid Shutdown function, so the off or open position shows that a rapid shutdown has been initiated. When this happens the inverter logs event 9033, which says Rapid Shutdown was triggered and the AC side was disconnected. With grid support enabled, the inverter can stay connected for a set ride-through time after the AC disconnect is operated, and only disconnects and starts the rapid shutdown if grid voltage does not come back. Some setups name a breaker as the initiator: a Generac SDS AC PV breaker turned off with its cover locked counts as the rapid shutdown initiator, and SMA inverters have a parameter that selects either the AC disconnect or a digital input. A dark display does not prove the inverter is off, because a failed internal part can also blank it, so check by eye that the AC and DC disconnects are in the OFF position.