PTC, short for PVUSA Test Conditions and also called Performance Test Conditions, is a rating condition used to state PV module and array output under conditions closer to real field operation than Standard Test Conditions. STC assumes 1000 W/m2 at AM 1.5 and a 25°C cell temperature, which tends to overestimate field performance because arrays rarely see that irradiance and temperature together. Training guides describe PTC as 1000 W/m2 irradiance, 45°C cell temperature and 1 m/s wind speed. The PTC parameters come from the Nominal Terrestrial Environment that defines NOCT, which uses a lower irradiance of 800 W/m2. To rate array or module power in the field, an I-V measurement taken under whatever conditions apply can be translated to the PTC condition or to the ASTM standard reporting condition. Because PTC accounts for realistic operating temperature, a module's PTC rating is a better guide to expected field output than its STC nameplate.