Concept
Nominal operating cell temperature
- ID
concept:nominal-operating-cell-temperature
- IRI
https://solarlattice.org/kb/concept/nominal-operating-cell-temperature
- Status
- active
- Also known as
- NOCT, NMOT
- Category
- Modules
- Concept kind
- physics
Nominal operating cell temperature (NOCT) is a defined set of irradiance and temperature conditions used to characterize solar cells, PV modules and PV inverters. One solution guide lists the NOCT conditions as 800 W/m2 irradiance, an Air Mass 1.5 G spectrum, 20 C, and a wind speed of 1 m/s, which give a nominal operating cell temperature of 45±2 C. These conditions are closer to real field operation than standard test conditions (STC). STC uses 1,000 W/m2 irradiance and a 25 C cell temperature. NOCT is listed with STC, PTC and normal operating conditions as one of the conditions used to rate modules. The PTC rating conditions were based on the Nominal Terrestrial Environment that defines NOCT. The difference is that the NOCT environment uses a lower irradiance of 800 W/m2. Cell temperature matters because hotter crystalline silicon cells give lower voltage and power and only slightly more current. Higher temperatures also reduce cell efficiency and lifetime. Temperature coefficients turn a difference in cell temperature into changes in a module's voltage, current and power output.
<!-- review notes
- sentence 2: support check: partial - Values match, but the passage lists 45±2 C as a separate item and cell temperature 20 C; 'give a nominal operating cell temperature' is a mild interpretation, and 'solution guide' source is not shown.
- sentence 3: support check: partial - STC values are stated, but the passages never say NOCT conditions are closer to real field operation than STC.
-->
Claims
related_to
c1 drafted · lead
Standard test conditions
Both are defined sets of irradiance, spectrum and temperature used to rate cells and modules; STC uses 1,000 W/m2 and 25 C cell temperature, NOCT uses 800 W/m2.
c2 drafted · lead
PVUSA test conditions rating
PTC parameters were derived from the Nominal Terrestrial Environment that defines NOCT; NTE specifies a lower irradiance (800 W/m2) than PTC (1000 W/m2).
c3 drafted · lead
Air mass
NOCT conditions specify an Air Mass 1.5 G spectral distribution.
c4 drafted · lead
Temperature coefficient
Cell operating temperature, which NOCT characterizes, drives voltage and power changes through the module temperature coefficients.
review note: support check: partial - Passages say cell temperature affects voltage/power via temperature coefficients, but do not link NOCT itself to temperature coefficients.