Concept
Power quality
- ID
concept:power-quality
- IRI
https://solarlattice.org/kb/concept/power-quality
- Status
- active
- Also known as
- voltage sags, swells, flicker, rapid voltage change, PQ
- Category
- Grid
- Concept kind
- electrical
Power quality describes how well the electricity supply suits the equipment that uses it. A power quality problem is any deviation in voltage, current or frequency that makes customer equipment misoperate or fail. Common power quality events include voltage sags (also called dips), swells, interruptions, flicker, harmonic distortion and phase unbalance. A voltage sag is a sudden drop in voltage while the load stays connected. Faults on the power system usually cause sags, but starting large motors can also cause them. A rapid voltage change is a quick shift in rms voltage between two steady states that stays inside the sag and swell thresholds. Switching, inrush currents and energizing a transformer can all cause one. Power quality problems can come from the utility, from your own site's equipment, or from a neighbouring facility. Equipment that is sensitive to disturbances can also be the source of them. Revenue and protection meters, such as Class A meters built to IEC 61000-4-30, log sags, swells, flicker and harmonics for this kind of analysis. Power quality analysis is also part of PV commissioning.
<!-- review notes
- sentence 1: support check: partial - u18 gives the power quality problem definition and u1 describes PQ as compatibility of supply with end-use equipment, but u1 only supports this loosely as a general definition.
- sentence 6: support check: partial - Class A IEC 61000-4-30 logging of sags, swells, flicker and harmonics and the commissioning power quality analysis section are supported, but 'revenue and protection meters' generally is not stated.
-->
Claims
related_to
c1 drafted · lead
Point of common coupling proposed
Rapid voltage change and flicker limits are judged at the PCC, and the utility may record flicker at or near the PCC.
c2 drafted · lead
Harmonic distortion
Harmonics and THD are tracked as power quality parameters.
c3 drafted · lead
Phase unbalance
Voltage and current unbalance are logged as power quality events or parameters.
c4 drafted · lead
Load inrush current
Start-ups, inrush currents and the switching of capacitor banks or transformers are listed as causes of rapid voltage changes.
c5 drafted · lead
IEEE 519 proposed
One utility points to IEEE 519 as guidance when it reviews flicker data.
c6 drafted · lead
Power quality analyzer
Where flicker is a concern, the utility may install a recording power quality meter.
c7 drafted · lead
SEL-735 Power Quality and Revenue Meter proposed
This meter complies with IEC 61000-4-30 Class A and measures flicker, sags, swells and interruptions.
c8 drafted · lead
Accuenergy Acuvim II power meter
It logs power quality events such as sags and swells, each with a timestamp.