Ground fault detection circuit
The ground fault detection circuit is the part of the inverter that provides DC ground fault protection. It uses residual current detection, as UL 1741 requires. If the PV array has a ground fault, the circuit senses the leakage current and raises an alarm, and the inverter stops operating. Some manuals state that the inverter shuts down when the leakage current goes above 500 mA. Other manuals point to static and dynamic trip thresholds that are set during commissioning or in the app. A ground fault is an unintended connection, or a loss of insulation, between the PV system and ground. A common cause is damaged conductor insulation, and electrical codes require devices that detect and interrupt ground faults. The detector itself can fail (Ground fault detector failure). In that case the inverter reports a ground fault current sensor or leakage current sensor fault code, such as Protect0310 or Protect0100. To clear a sensor fault, cycle both the AC and DC switches off and on, waiting one minute between off and on. If the fault does not clear, contact service or replace the inverter. Inverters also monitor DC insulation to ground, but this monitoring may not show where the fault is. To locate it, technicians measure the voltage from each pole to ground or test the insulation resistance.
<!-- review notes
- sentence 3: support check: partial - The 500 mA shutdown (u3, u36) and the references to static/dynamic trip thresholds are stated, but the passages say only to see the Commissioning, Chapter 5/6 or App Interface sections, not that the thresholds are set during commissioning or in the app.
- sentence 5: support check: partial - Protect0310 (GFCI sensor abnormal) and Protect0100 (leakage current sensor fault) are in the passages, but none of them uses the name 'Ground fault detector failure' or says the detector itself failing is the cause. -->
Referenced by
- CPS SCA25KTL-208 Protect0100
affectsc4 - CPS SCA25KTL-480 Protect0100
affectsc4 - CPS SCA50-100K-T Protect0100
affectsc4 - CPS SCA50-100K-T Protect0310
affectsc4 - CPS SCA50-100K-T Protect0390
affectsc4 - CPS SCH100-125KTL Protect0100
affectsc4 - CPS SCH125KTL-AIO Protect0100
affectsc4 - CPS SCH200-250K-T Protect0390
affectsc4 - CPS SCH275KTL Protect0100
affectsc4 - CPS SCH350KTL Protect0100
affectsc4 - Fronius Symo 607
affectsc2 - KACO new energy blueplanet TL3 169
affectsc3 - KACO new energy blueplanet TL3 31
affectsc4 - Schneider Electric CL125 041
affectsc4 - SMA STP-X-US 6202
affectsc3 - SMA SC-CP-XT 3502
affectsc3 - SMA SC-CP-XT 7708
affectsc3 - SMA SC-CP-XT 7714
affectsc3 - Current sensor fault
affectsc3 - Ground fault detector failure
affectsc1