Solar Lattice

Symptom

Bypassed substring

ID
symptom:substring-loss
IRI
https://solarlattice.org/kb/symptom/substring-loss
Status
active
Also known as
OC substrings, open substrings

A bypassed or lost substring means one section of a module no longer delivers power. The current either flows through the bypass diode or the substring is cut off, and the module loses that share of its output. In infrared images, a whole substring looks warmer than its neighbours. Open-circuit substrings from bad junction box connections typically run 5 to 10 K hotter than active ones. In electrical data and IV traces, module open-circuit voltage is lower. Affected modules can show only about two thirds of normal voltage and power. Possible causes include a shorted or open bypass diode, cold solder joints or other junction box failures, and broken cell interconnections that block current in a cell string and force the diode to conduct. Snow or soiling covering part of the array can also cause substring mismatch. In that case the loss follows the weather: it starts abruptly after snowfall and fades as the snow melts or slides off. To find the cause, compare IR, EL, IV curves and a visual check of the junction box for burn marks. An open diode or failure mode A does not show in normal IR, so run a night string reverse-bias test and look for unusually high reverse voltage. Treat one confirmed junction box connection failure as a fleet risk. These defects tend to affect a whole production batch and can lead to arcing or fire, so test all modules.

<!-- review notes

Claims

observed_as

c1 verified · fact Warm substring in IR image

A whole substring appears overheated in thermography. With a short-circuited bypass diode or substring the heating pattern can be irregular. Open-circuit substrings from cold solder joints in the junction box (failure modes B and C) show up in IRT, but failure mode A does not.

verified by: joshuahamsaverified on: 2026-10-20

c3 verified · fact Low open-circuit voltage

When a substring is lost, module Voc drops. In one batch, defective modules with unstable junction box connections delivered only 2/3 of normal voltage and power.

verified by: joshuahamsaverified on: 2026-10-20

c4 verified · fact High string reverse voltage

Night string test applying a small reverse current (3% to 5% of rated Isc). An unusually high reverse voltage points to an open or unconnected bypass diode or failure mode A. Night IR then shows the slightly warmed substring.

verified by: joshuahamsaverified on: 2026-10-20

temperature_rise

c2 verified · fact 5–10 K

Conditions: Open-circuit substrings or module strings caused by unreliable junction box connections, compared with active strings during IRT inspection

verified by: joshuahamsaverified on: 2026-10-20