PID voltage instability
The manual says to watch the inverter for 5 minutes to see if the alarm clears by itself, and to call after-sales service if it does not. Do not mix it up with Fault7040, the PID over-voltage warning, which uses Bit4 of the same register. The alarm concerns the inverter's PID function, which includes a nighttime PID voltage setting for P-type panels. Before enabling any anti-PID or PID repair function, confirm that the polarity of the module voltage to ground suits the installed modules, because a wrong voltage scheme can make the function ineffective or damage the modules.