Symptom
Open string circuit
- ID
symptom:open-circuit
- IRI
https://solarlattice.org/kb/symptom/open-circuit
- Status
- active
- Also known as
- OC substrings, open-circuited
An open circuit is a break in the current path of a module substring, a whole module or a full string, so that part stops producing. Common causes are connector defects, damaged DC cables and junction box failures, including cold solder joints and loose or corroded contacts. In IR thermography under load, an open substring or module string looks warmer than the active strings. A full string loss can be seen this way too, but the faulty module can stay hard to locate. Electrically, an open substring loses its power and lowers module Voc. A string Voc check against identical strings or the expected value also catches missing interconnections. In monitoring data, look for a loss in performance and compare string currents to find the string that is underperforming. To tell the causes apart, first inspect connectors and cables visually and by touch under safe isolation. Then check junction boxes for burn marks, open lids or detachment, and use IR to find hot connections. If an open circuit traces back to the junction box, replacing the module is advised because repairs may start new fires.
<!-- review notes
- sentence 1: support check: partial - Passages describe open-circuited module/cell strings and substring power loss, but do not define an open circuit as a break in the current path; it is mostly implied.
- sentence 4: support check: partial - Substring power loss and Voc reduction are stated, and string Voc comparison catches missing interconnections, though the latter is about missing module interconnections in strings rather than open substrings specifically.
- sentence 6: support check: partial - Visual/tactile inspection under isolation and IR are supported, and junction box visual/thermal inspection is stated, but the sequencing and specific checks for burn marks, open lids or detachment are only partly in the passages, though lid defects and burnt boxes are mentioned.
-->
Claims
observed_as
c1 verified · fact
Warm substring in IR image
Open-circuited substrings or module strings show up warmer than active ones in thermography taken under load. Seen in batches of modules with cold solder joints in the outer junction box.
verified by: joshuahamsaverified on: 2026-10-20review note: support check: partial - Passages say OC substrings appear hotter in IRT and are seen from cold solder joints in outer junction box batches, but 'under load' and the 'neighbouring modules under same irradiance' conditions are not stated.
c3 verified · fact
Low open-circuit voltage
An open-circuited substring loses its power and lowers module Voc.
verified by: joshuahamsaverified on: 2026-10-20review note: support check: partial - Passage says open sub-string loses power and Voc is reduced, but does not mention string voltage or module voltage comparison against peers.
c4 verified · fact
Production loss alarm
Monitoring tools may flag a performance loss when a junction box failure leaves an open-circuit configuration.
verified by: joshuahamsaverified on: 2026-10-20review note: support check: partial - Monitoring tools might detect performance loss from open-circuit configurations is stated, but string current dropping to zero and DC power falling at constant irradiance are not specified.
temperature_rise
c2 drafted · lead
5–10 K
Conditions: Open-circuited substrings or module strings compared with active strings during IR thermography inspection