This symptom is a weather-normalized production deficit that stays in place after rain instead of recovering, as ordinary dust soiling normally does. Its main known cause is widespread fungal soiling: biofilms and other persistent biological deposits on the module glass that rain does not wash off but manual cleaning removes. It is easy to mistake for ordinary dust, pollen or a weather-normalization error. Granular dust soiling usually recovers partly or fully after enough rain, so the lack of recovery after rain is the key difference. Some particles can become cemented to the glass, and rain may not remove them either. In that case active cleaning is needed. Check first by comparing rain events and cleaning logs with SCADA, irradiance and weather-normalized production. Look for a repeatable step-up after cleaning where rain did not bring output back. Confirm biofilm with a close visual inspection or handheld microscopy. Check several areas of the array, because biological deposits can be patchy. Where this loss is confirmed, add cleaning to the maintenance plan and base forecasts on cleaning results, not on the assumption that rain resets the loss.

<!-- review notes

Claims

observed_as

c1 verified · fact No recovery after rain

Weather-normalized production deficit stays after rain events; with fungal bio-soiling only manual cleaning recovers it.

verified by: review-workflowverified on: 2026-10-20

c2 drafted · lead Production step after cleaning

A repeatable step-up in normalized production after manual cleaning, where rain had not restored expected output, is the key evidence for biological soiling.

typical_power_loss

c3 verified · fact 5–11 PERCENT

Conditions: Persistent fungal bio-soiling losses at solar farms in North Carolina (humid subtropical U.S.), recovered only by manual cleaning, from 2024 field work

verified by: review-workflowverified on: 2026-10-20review note: support check: partial - 5-11% persistent losses in North Carolina recovered only by manual cleaning are stated, but 'typical' is not used; they are reported losses.