Flying capacitor undervoltage
The manual lists it in the warning faults table, not among the trip faults. First, look at the input voltage deviation between the PV inputs on the inverter LCD. If one branch has a clearly lower input voltage than the rest, disconnect that branch and restart the inverter. If the warning stays after these steps, contact CPS Customer Service. Before opening the cover, wait at least five minutes after disconnecting all supply sources, because the capacitors hold stored energy.