Damaged DC cables and connectors can look brittle, cracked, broken or whitened, and in worse cases melted or burned. This damage usually points to a cable defect or a connector defect, and either one can cause insulation faults, ground faults, overheating, lost production and a risk of fire. A thermography check often shows the affected connector or cable running hot early on, before it fails completely. If the damage is on a connector, open it and look for corrosion. Corrosion points to a connector defect rather than a fault along the cable run. Cracks in a module backsheet can also break down insulation and lead to ground faults, so check whether the damage is on the wiring or on the module itself. Start with a visual inspection. Then test insulation resistance, do a thermal inspection, compare string currents, and isolate the circuit to find the fault.