Cracked or brittle housing turns up in visual inspection on two main parts: the module junction box (its housing and lid) and DC connectors or cables. On a junction box, the housing or lid may look weathered, brittle, cracked, warped, melted or burned. The lid may be loose or missing, and the seals at the wire entry or lid may be squeezed, broken, brittle or gone. If the cracks are on a connector or cable, suspect a connector defect. A damaged connector can also look melted, burned, broken or whitened, and opened connectors may show corrosion. If the cracks are on the junction box, suspect a junction box failure. Water can get in through a brittle or cracked housing or a missing seal and corrode the contacts inside. Start with a visual check. Then do an infrared scan under load, because affected connectors often run hot at an early stage. Make the circuit safe before any hands-on or tactile inspection. Damaged connectors can cause arcing, ground faults and fire.