Overtemperature in connection area

First, watch the inverter for 5 minutes to see whether the alarm clears by itself. If it keeps coming back, contact after-sales service. Fault5020 and Fault5030 report a faulty connector temperature sensor rather than real heating. For those codes, check that the bulkhead connectors are properly connected. The most likely failure mode behind a hot connector is a connector defect. Resistance heating there can lead to arcing, ground faults and fire. These defects usually come from installation problems: poor crimping, mismatched or cross-mated connectors, or low-quality materials. Ageing from UV and humidity is a less common cause. An infrared scan under load usually shows an affected connector as a hotspot at an early stage. Compare string currents as well. Isolate the circuit safely before a visual and hands-on check. Look for melted, burned, brittle, cracked or whitened connectors, and for corrosion inside opened ones.

<!-- review notes

Claims

observed_as

c1 verified · fact Hot electrical connection

Damaged DC connectors often show overheating or hotspots in an early state during thermography; IR inspection should be done under load.

verified by: review-workflowverified on: 2026-10-23

c2 drafted · lead Visible burn marks

A damaged connector may look melted, burned, brittle, cracked or whitened; opened connectors may show corrosion.

review note: review: partial - The note matches the rows' description of damaged connectors, but the passages never say burn marks are how overtemperature specifically shows up; they list burned appearance only as a general sign of damage.

c3 drafted · lead Corroded connector contacts

Corrosion can be seen once affected connectors are opened.

review note: review: partial - The rows support the note that opened connectors can show corrosion, but they do not tie corrosion to connector overtemperature as an observation of it.