SunSpec model 713, DER Storage Capacity, is an information model in the SunSpec 700 series. It defines a group of data points and does not set a transport. SunSpec models are standard Modbus-based information models used to monitor and control DER devices. SunSpec as a whole is described as an application-layer protocol for DER interoperability. SMA's SunSpec Modbus technical information lists model 713 in the 700 series. It notes that model 713 is only available on battery inverters. The 700 series is meant to replace the older 100 series so devices can meet IEEE 1547:2018. SMA says it will add the 700 series in a future firmware version, and the 100 series can still be used but is marked outdated. Each SunSpec model starts with a header that gives its identity and length. A device may not support every register in a model, so check the vendor map and only use the registers it supports. On SMA products, the SunSpec Modbus profile starts at register number 40001.

<!-- review notes

Claims

part_of

c1 verified · fact SunSpec information models

Model 713 DER Storage Capacity is one of the 700 series SunSpec information models; per SMA documentation it applies only to battery inverters.

verified by: review-workflowverified on: 2026-10-24