Solar Lattice

Program

SREC production reporting

ID
prog:srec-reporting
IRI
https://solarlattice.org/kb/prog/srec-reporting
Status
active
Also known as
SREC registration, SREC incentive reporting, Automated Incentive Reporting, Incentive Reporting Services
Category
REC registry
Program kind
incentive

Locus Energy offers an automated incentive reporting service. It validates and submits SREC generation data for 11 incentive programs across the country and also answers questions about SRECs. Interval data from the revenue-grade production meter is combined into a monthly submission. The program checks the data and then issues SRECs to the account holder. To enroll, register the system with the program, such as Mass CEC PTS or PJM GATS. Name Locus Energy as System Representative or Third Party Reporter, then email the completed reporting setup form to the Locus reporting team. For Massachusetts you also send the Automated Incentive Reporting Contract. The setup form asks for system IDs, the LGate comm device ID, the date in service and installer contact details. Setup forms must arrive by the last business day of the month to be reported for that month. If a form is late, no SRECs are lost, because the next report covers both periods. The LGate stores about two months of data. If it stays offline longer than that, send the reporting team a recent inverter or backup meter reading so the missing generation can be accounted for. Contracts run for five or 10 years and can be renewed, depending on the program.

Claims

issued_by

c1 drafted · lead Locus Energy proposed

Locus Energy runs an automated incentive reporting team that validates and submits generation data to the programs.

applies_to

c2 drafted · lead Locus Energy LGate gateway proposed

The LGate production meter records generation at 5 minute intervals and holds about two months of data in internal memory.

c3 drafted · lead United States proposed

Covers 11 incentive programs nationwide, including Mass CEC/PTS, PJM/GATS, NEPOOL, WREGIS, the CSI utilities and MRETS.

c4 verified · fact Massachusetts proposed

Reporting to the Massachusetts CEC PTS program; Locus must be designated as System Representative.

verified by: review-workflowverified on: 2026-10-24

c5 drafted · lead PJM market area proposed

Reporting to GATS PJM-EIS; Locus must be designated as Third Party Reporter.

warranty_term

c6 drafted · lead nominal 10 YR

Conditions: Longer of the two incentive reporting subscription contract options; renewal depends on the program and its enrollment rules

review note: review: partial - The passage supports a 10-year contract as the longer of two subscription options, renewable depending on the program and its enrollment rules, but it describes a service subscription contract, not a warranty term, so the 'warranty term' relation is not…