On Fronius Galvo, Primo and Symo inverters, checking the removable USB drive is the first step for storage warnings shown on the display. These are 731 (drive not supported), 733 (no drive inserted), 736 (read or write error), 738 (log file not saved), 743 (error during an update) and 745 (defective update file). Make sure a drive is inserted and seated. Check its file system and the files on it, and replace the drive if it is not supported or keeps failing. If the log file cannot be saved, the drive may be full or write-protected: free up space and remove the write protection, then check or replace the drive if needed. If an update fails, run the update again and check the drive. If the update file is defective, download it again before checking or replacing the drive. Wait until OK shows or the Data Transfer LED has stopped flashing and is off before you pull the drive. Removing it earlier can lose data. If the status code stays after these checks, call a Fronius-trained service technician.