Configuration file verification means confirming that a configuration file is right for the inverter before you import it. It applies when the inverter rejects an import with event 7347 (Incompatible file) or event 7348 (Incorrect file format). Event 7347 means the selected configuration file does not suit this inverter. The fix is to choose a file that matches the device and then run the import again. Event 7348 means the file is not in the required format or is damaged. Check that the file has the correct format and is intact, then retry the import. To adopt a configuration from a file, you need an inverter configuration that has already been saved to a file. In the user interface, select the option to adopt the configuration from a file, browse to the file and import it. Event 7350 is only a status message. It shows that the configuration file is being transferred. Checking the file does not fix every import problem. If the import fails because of user rights (event 7349), log in as Installer and import the file again.