Energy ratio analysis compares the energy a system actually produced each day with the energy a PV model expects from measured irradiance and module temperature. The ratio can be calculated separately for each inverter and each production meter, and a daily check passes when output stays within a set band around the expected energy. Results depend on a well-tuned PV model and accurate irradiance and temperature data, and the check is switched off when snow is present. Soiling losses show up as a slow drop in the energy ratio over several days, which a pattern-matching routine picks up. Usually five or more days of data are needed to detect a soiling event, and spans shorter than four days are not detected. Soiling loss can be measured against an ideal ratio of 1.0 for a model tuned to a clean system, or counted from zero at the start of each soiling event. A simpler monthly version, the insolation-adjusted estimated energy ratio, divides the ratio of measured to estimated AC energy by the ratio of measured to estimated insolation.

<!-- review notes

Claims

produces

c1 verified · fact Gradual energy ratio decline

Soiling loss is flagged by pattern matching on the energy ratio as a slow loss over several days; typically 5 or more days of data are needed and spans shorter than 4 days are not detected. Loss size comes from the slope, the gap between ideal and daily average energy ratio, and actual production.

verified by: joshuahamsaverified on: 2026-10-20review note: support check: partial - Soiling pattern matching on energy ratio, 5+ days, <4 days undetected, and loss-size basis are stated, but the specific signals (no matching irradiance drop, module temperature input, daily AC energy falling) are only loosely supported and 'gradual decline' is described as gradual performance loss.

c2 verified · fact Energy ratio out of range

Daily energy of each inverter and production meter is compared with expected energy from a full PV model; the check passes when produced energy is between 70% and 110% of expected. The test is disabled by snow.

verified by: joshuahamsaverified on: 2026-10-20