Shorted diode reading

ID
meas:shorted-diode-reading
IRI
https://solarlattice.org/kb/meas/shorted-diode-reading
Status
active
Also known as
short-circuited diode, Short-circuited bypass diodes

The best way to find out whether a bypass diode is shorted or open is to test it directly with a multimeter set to diode or ohmmeter mode. Bypass diodes fail in one of two main ways, short circuit or open circuit, and short circuits are reported more often than open circuits. A diode reads as shorted if it is physically shorted inside the junction box, if it was mounted the wrong way round, or if lightning or static discharge exposed it to high voltage. A shorted bypass diode permanently lowers the module's voltage capability and can shift the maximum power point of the whole array. Before you take a direct diode reading, a shorted diode may first show up as an open-circuit voltage lower than expected, or as a step or notch in the IV curve. If the blocking diode voltage falls outside the pass range, investigate further to find out whether the diode failed on its own or because of another system fault.